Literature DB >> 11578728

A linac-based stereotactic irradiation technique of uveal melanoma.

K Dieckmann1, J Bogner, D Georg, M Zehetmayer, G Kren, R Pötter.   

Abstract

PURPOSE: To describe a stereotactic irradiation technique for uveal melanomas performed at a linac, based on a non-invasive eye fixation and eye monitoring system.
METHODS: For eye immobilization a light source system is integrated in a standard stereotactic mask system in front of the healthy eye: During treatment preparation (computed tomography/magnetic resonance imaging) as well as for treatment delivery, patients are instructed to gaze at the fixation light source. A mini-video camera monitors the pupil center position of the diseased eye. For treatment planning and beam delivery standard stereotactic radiotherapy equipment is used. If the pupil center deviation from a predefined 'zero-position' exceeds 1 mm (for more than 2 s), treatment delivery is interrupted. Between 1996 and 1999 60 patients with uveal melanomas, where (i) tumor height exceeded 7 mm, or (ii) tumor height was more than 3 mm, and the central tumor distance to the optic disc and/or the macula was less than 3 mm, have been treated. A total dose of 60 or 70 Gy has been given in 5 fractions within 10 days.
RESULTS: The repositioning accuracy in the mask system is 0.47+/-0.36 mm in rostral-occipital direction, 0.75+/-0.52 mm laterally, and 1.12+/-0.96 mm in vertical direction. An eye movement analysis performed for 23 patients shows a pupil center deviation from the 'zero' position<1 mm in 91% of all cases investigated. In a theoretical analysis, pupil center deviations are correlated with GTV 'movements'. For a pupil center deviation of 1 mm (rotation of the globe of 5 degrees ) the GTV is still encompassed by the 80% isodose in 94%.
CONCLUSION: For treatments of uveal melanomas, linac-based stereotactic radiotherapy combined with a non-invasive eye immobilization and monitoring system represents a feasible, accurate and reproducible method. Besides considerable technical requirements, the complexity of the treatment technique demands an interdisciplinary team continuously dedicated to this task.

Entities:  

Mesh:

Year:  2001        PMID: 11578728     DOI: 10.1016/s0167-8140(01)00413-3

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  5 in total

1.  Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma.

Authors:  Omar Iskanderani; Dominique Béliveau-Nadeau; Robert Doucet; Geneviève Coulombe; Deborah Pascale; David Roberge
Journal:  Technol Cancer Res Treat       Date:  2017-02-07

2.  Dosimetric advantage of volumetric modulated arc therapy in the treatment of intraocular cancer.

Authors:  Zhenxiang Deng; Lanxiao Shen; Xiaomin Zheng; Yongqiang Zhou; Jinling Yi; Ce Han; Congying Xie; Xiance Jin
Journal:  Radiat Oncol       Date:  2017-05-10       Impact factor: 3.481

3.  Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma.

Authors:  Toshihiko Inoue; Norihisa Masai; Hiroya Shiomi; Ryoong-Jin Oh; Kenji Uemoto; Noriyasu Hashida
Journal:  J Radiat Res       Date:  2017-05-01       Impact factor: 2.724

4.  Stereotactic radiotherapy in the treatment of ocular melanoma: a noninvasive eye fixation aid and tracking system.

Authors:  S M Jaywant; E K Osei; S Ladak
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

5.  Gamma Knife Perfexion® radiosurgery and endo diode laser thermotherapy for choroidal melanoma with technical analysis: A case report.

Authors:  Yi-Chieh Tsai; Chun-Yuan Kuo; Jia-Wei Lin; Shun-Tai Yang; Shih-Chung Lai; Jo-Ting Tsai
Journal:  Oncol Lett       Date:  2017-10-31       Impact factor: 2.967

  5 in total