Computational fluid dynamics and experimental validation of a microaxial blood pump.

J Apel1, F Neudel, H Reul.   

Abstract

Intravascular application of microaxial blood pumps as heart assist devices requires a maximum in size reduction of the pump components. These limitations affect the design process in many ways and restrict the number of applicable experimental procedures, but a detailed knowledge of the hemodynamics of the pump is of great interest for efficiency enhancement and reduction of blood trauma and thrombus formation. Computational fluid dynamics (CFD) offers a convenient approach to this goal. In this study, the inlet, vane, and outlet regions of a microaxial blood pump used as an intraaortic left ventricular assist device are analyzed by CFD and 3-dimensional (3-D) particle tracking velocimetry (PTV). For this purpose, a mock loop is set up that facilitates 3-D flow visualization. Flow in the main part of this testing device is modeled and computed by means of CFD. Pump head/flow (HQ) characteristics, axial pressure distribution, and particle images are then compared with numerical flow data. Results show that the pump performance characteristics, as well as inlet and outlet swirl predicted by the CFD model, are quite accurate compared with measured data. Proper boundary condition definitions and spatial discretization topology requirements for satisfactory results are discussed.

Entities:  

Mesh:

Year:  2001        PMID: 11575836     DOI: 10.1097/00002480-200109000-00031

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

Review 1.  The use of computational fluid dynamics in the development of ventricular assist devices.

Authors:  Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Eng Phys       Date:  2010-11-13       Impact factor: 2.242

2.  Evaluation of a pumping assist lung that uses a rotating fiber bundle.

Authors:  Robert G Svitek; Brian J Frankowski; William J Federspiel
Journal:  ASAIO J       Date:  2005 Nov-Dec       Impact factor: 2.872

3.  Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs.

Authors:  Michalis Xenos; Gaurav Girdhar; Yared Alemu; Jolyon Jesty; Marvin Slepian; Shmuel Einav; Danny Bluestein
Journal:  J Biomech       Date:  2010-05-21       Impact factor: 2.712

Review 4.  Towards non-thrombogenic performance of blood recirculating devices.

Authors:  D Bluestein; K B Chandran; K B Manning
Journal:  Ann Biomed Eng       Date:  2010-02-04       Impact factor: 3.934

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.