Only carbon dioxide absorbents free of both NaOH and KOH do not generate compound A during in vitro closed-system sevoflurane: evaluation of five absorbents.

L F Versichelen1, M P Bouche, G Rolly, J F Van Bocxlaer, M M Struys, A P De Leenheer, E P Mortier.   

Abstract

BACKGROUND: Insufficient data exist on the production of compound A during closed-system sevoflurane administration with newer carbon dioxide absorbents.
METHODS: A modified PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow at the top of the bellow approximately/= 160 ml/min CO2; outflow at the Y piece of the lung model approximately/= 200 ml/min, simulating oxygen consumption). Ventilation was set to obtain an end-tidal carbon dioxide partial pressure of approximately 40 mmHg. Various fresh carbon dioxide absorbents were used: Sodasorb (n = 6), Sofnolime (n = 6), and potassium hydroxide (KOH)-free Sodasorb (n = 7), Amsorb (n = 7), and lithium hydroxide (n = 7). After baseline analysis, liquid sevoflurane was injected into the circuit by syringe pump to obtain 2.1% end-tidal concentration for 240 min. At baseline and at regular intervals thereafter, end-tidal carbon dioxide partial pressure, end-tidal sevoflurane concentration, and canister inflow (T degrees(in)) and canister outflow (T degrees(out)) temperatures were measured. To measure compound Ainsp concentration in the inspired gas of the breathing circuit, 2-ml gas samples were taken and analyzed by capillary gas chromatography plus mass spectrometry.
RESULTS: The median (minimum-maximum) highest compound Ainsp concentrations over the entire period were, in decreasing order: 38.3 (28.4-44.2)* (Sofnolime), 30.1 (23.9-43.7) (KOH-free Sodasorb), 23.3 (20.0-29.2) (Sodasorb), 1.6 (1.3-2.1)* (lithium hydroxide), and 1.3 (1.1-1.8)* (Amsorb) parts per million (*P < 0.01 vs. Sodasorb). After reaching their peak concentration, a decrease for Sofnolime, KOH-free Sodasorb, and Sodasorb until 240 min was found. The median (minimum-maximum) highest values for T degrees(out) were 39 (38-40), 40 (39-42), 41 (40-42), 46 (44-48)*, and 39 (38-41) degrees C (*P < 0.01 vs. Sodasorb), respectively.
CONCLUSIONS: With KOH-free (but sodium hydroxide [NaOH]-containing) soda limes even higher compound A concentrations are recorded than with standard Sodasorb. Only by eliminating KOH as well as NaOH from the absorbent (Amsorb and lithium hydroxide) is no compound A produced.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11575550     DOI: 10.1097/00000542-200109000-00030

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  4 in total

1.  Comparison of the renal safety between carbon dioxide absorbent products under sevoflurane anesthesia: a pilot study.

Authors:  Hyung-Chul Lee; Donguk Kim; Wonsik Ahn; Jiyeon Sim; Yehoon Chung
Journal:  Korean J Anesthesiol       Date:  2012-07-24

2.  Performance of a new carbon dioxide absorbent, Yabashi lime® as compared to conventional carbon dioxide absorbent during sevoflurane anesthesia in dogs.

Authors:  Kei Kondoh; Ayman Atiba; Kiyoshi Nagase; Shizuko Ogawa; Takashi Miwa; Teruya Katsumata; Hiroshi Ueno; Yuji Uzuka
Journal:  J Vet Med Sci       Date:  2015-05-04       Impact factor: 1.267

Review 3.  The closed circuit and the low flow systems.

Authors:  S Parthasarathy
Journal:  Indian J Anaesth       Date:  2013-09

4.  Predicting cost of inhalational anesthesia at low fresh gas flows: impact of a new generation carbon dioxide absorbent.

Authors:  Alastair E Moody; Bryce D Beutler; Catriona E Moody
Journal:  Med Gas Res       Date:  2020 Apr-Jun