Applied potential tomography in liquid gastric emptying measurement: design, assembling, calibration, and clinical application.

F Y Chang1, C L Lu, C Y Chen, S D Lee, D S Tsai, S E Fu.   

Abstract

The present study aimed to validate the accuracy of a homemade applied potential tomography (APT) apparatus for liquid gastric emptying (GE). Twelve electrodes were placed in a circular array around the subjects. Ten electrodes in a rotated order recorded electrical current delivered from a driving pair of electrodes. Based on tomography, averaged signals of changed resistivity were constructed to display area changes. Six beakers were respectively placed into a saline-filled Perspex tank to measure their cross-sections. True beaker cross-sections are 2.01, 15.9, 18.8, 30.19, 38.48, and 63.61 cm2, respectively, whereas APT generated cross-sections were 7.9 +/- 2.9, 16.7 +/- 3.3, 22.4 +/- 4.9, 28 +/- 4.8, 48.7 +/- 7.6, 67 +/- 6.1 cm2, respectively (r = 0.98, P < 0.001). Twenty-four healthy males ingested 500-ml test solution to assess GE using both APT and scintigraphy. Only 20 (83.3%) subjects had a successful measurement. The APT half emptying time was 15.6 +/- 4.8 min, whereas scintigraphy was 21.9 +/- 6.3 min (r = 0.67, P < 0.01). In conclusion, our APT apparatus is a simple, noninvasive, and inexpensive way to assess liquid GE. Its clinical usefulness is confirmed using both phantom and human models.

Entities:  

Mesh:

Year:  2001        PMID: 11575434     DOI: 10.1023/a:1010614526685

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  21 in total

Review 1.  Omeprazole.

Authors:  P N Maton
Journal:  N Engl J Med       Date:  1991-04-04       Impact factor: 91.245

2.  Applied potential tomography. Noninvasive method for measuring gastric emptying of a solid test meal.

Authors:  Y F Mangnall; D D Kerrigan; A G Johnson; N W Read
Journal:  Dig Dis Sci       Date:  1991-12       Impact factor: 3.199

3.  Gastric emptying patterns of a liquid meal in newborn infants measured by epigastric impedance.

Authors:  A Lange; P Funch-Jensen; P Thommesen; P O Schiøtz
Journal:  Neurogastroenterol Motil       Date:  1997-06       Impact factor: 3.598

4.  Measurement by epigastric impedance of gastric emptying in diabetic autonomic neuropathy.

Authors:  S G Gilbey; P J Watkins
Journal:  Diabet Med       Date:  1987 Mar-Apr       Impact factor: 4.359

5.  Applications of applied potential tomography (APT) in respiratory medicine.

Authors:  N D Harris; A J Suggett; D C Barber; B H Brown
Journal:  Clin Phys Physiol Meas       Date:  1987

6.  Measurement of gastric emptying rates by radioactive isotope scanning and epigastric impedance.

Authors:  J A Sutton; S Thompson; R Sobnack
Journal:  Lancet       Date:  1985-04-20       Impact factor: 79.321

Review 7.  Methods for the assessment of gastric emptying in humans: an overview.

Authors:  R J Maughan; J B Leiper
Journal:  Diabet Med       Date:  1996-09       Impact factor: 4.359

8.  Peripartum changes in gastric emptying.

Authors:  B K Sandhar; R H Elliott; I Windram; D J Rowbotham
Journal:  Anaesthesia       Date:  1992-03       Impact factor: 6.955

9.  Effects of posture on gastric emptying of nonnutrient liquids and antropyloroduodenal motility.

Authors:  M Anvari; M Horowitz; R Fraser; A Maddox; J Myers; J Dent; G G Jamieson
Journal:  Am J Physiol       Date:  1995-05

10.  Noninvasive measurement of gastric emptying in obstetric patients.

Authors:  G M O'Sullivan; A J Sutton; S A Thompson; L E Carrie; R E Bullingham
Journal:  Anesth Analg       Date:  1987-06       Impact factor: 5.108

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.