Literature DB >> 11573621

Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb.

N W Linton1, R A Linton.   

Abstract

We have developed a new pulse contour cardiac output (PulseCO) algorithm based on frequency analysis studies of the arterial system. PulseCO was compared with thermodilution cardiac output (TDCO) in 10 patients undergoing cardiac surgery. Results from one patient were unsuitable for analysis. In the remaining nine patients, 142 TDCO determinations were compared with PulseCO after logarithmic transformation and after being normalized by the initial cardiac output in each patient. Each determination was usually the average of three measurements. Least squares regression gave y = 0.77 x (r2 = 0.81) and the limits of agreement were from -26% to +21%. The accuracy of PulseCO in determining short-term changes in cardiac output was assessed by comparing the ratios of consecutive PulseCO determinations with the ratios of the corresponding, consecutive TDCO determinations. Least squares regression gave y = 0.71 x (r2 = 0.70) and the limits of agreement were from -21% to +25%. After phenylephrine had been given to five patients, PulseCO showed an increase in systemic vascular resistance consistent with the known pharmacological actions of the drug. The PulseCO algorithm was incorporated into a computer program that acquires arterial pressure data from an analogue-to-digital converter and displays beat-to-beat trend values.

Entities:  

Mesh:

Year:  2001        PMID: 11573621     DOI: 10.1093/bja/86.4.486

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  15 in total

Review 1.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

2.  Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock.

Authors:  Michael T Ganter; Jamal A Alhashemi; Adel M Al-Shabasy; Ursina M Schmid; Peter Schott; Sanaa A Shalabi; Ahmed M Badri; Sonja Hartnack; Christoph K Hofer
Journal:  J Clin Monit Comput       Date:  2015-02-27       Impact factor: 2.502

3.  Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform: a comparison with pulmonary thermodilution and echocardiographic methods.

Authors:  Jani Penttilä; Amir Snapir; Erkki Kentala; Juha Koskenvuo; Jussi Posti; Mika Scheinin; Harry Scheinin; Tom Kuusela
Journal:  Eur J Clin Pharmacol       Date:  2006-03-29       Impact factor: 2.953

4.  Subject-specific model estimation of cardiac output and blood volume during hemorrhage.

Authors:  Maxwell Lewis Neal; James B Bassingthwaighte
Journal:  Cardiovasc Eng       Date:  2007-09

5.  Ability of pulse contour and esophageal Doppler to estimate rapid changes in stroke volume.

Authors:  Scott R Gunn; Hyung Kook Kim; Peter W J Harrigan; Michael R Pinsky
Journal:  Intensive Care Med       Date:  2006-07-28       Impact factor: 17.440

6.  Noninvasive assessment of cardiac output by brachial occlusion-cuff technique: comparison with the open-circuit acetylene washin method.

Authors:  Pavol Sajgalik; Vaclav Kremen; Alex R Carlson; Vratislav Fabian; Chul-Ho Kim; Courtney Wheatley; Vaclav Gerla; John A Schirger; Thomas P Olson; Bruce D Johnson
Journal:  J Appl Physiol (1985)       Date:  2016-10-20

Review 7.  Perioperative Haemodynamic Optimisation.

Authors:  Hollmann D Aya; Maurizio Cecconi; Andrew Rhodes
Journal:  Turk J Anaesthesiol Reanim       Date:  2014-04-01

8.  Effects of vasodilation on cardiac output measured by PulseCO.

Authors:  Koichi Yamashita; Tomoki Nishiyama; Takeshi Yokoyama; Hidehiro Abe; Masanobu Manabe
Journal:  J Clin Monit Comput       Date:  2007-09-25       Impact factor: 2.502

Review 9.  Monitoring cardiac function in intensive care.

Authors:  S M Tibby; I A Murdoch
Journal:  Arch Dis Child       Date:  2003-01       Impact factor: 3.791

Review 10.  Equipment review: new techniques for cardiac output measurement--oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis.

Authors:  Christine Berton; Bernard Cholley
Journal:  Crit Care       Date:  2002-04-25       Impact factor: 9.097

View more