Literature DB >> 1157307

Kinetic enzymatic method for determining serum creatinine.

G A Moss, R J Bondar, D M Buzzelli.   

Abstract

Creatinine amidohydrolase is used to measure serum creatinine in a totally enzymatic procedure. Creatine, produced by hydrolysis, is acted upon by creatine kinase, and then by pyruvate kinase and lactate dehydrogenase, to result in a change in absorbance at 340 nm. The amount of creatinine present is related to the rate of change in A340 and is determined from a standard curve. Absorbance and concentration are linearly related to 100 mg/liter and only 250 mul of serum is required. At 1.0 g/liter, heparin, oxalate, citrate, ethylenediaminetetraacetate, ascorbate, or glucose had no significant effect on the accurate determination of creatinine; higher concentrations (30 g/liter) had inhibitory effects on the test. Analytical recovery of creatinine added to either normal or abnormal sera averaged 102%. When results of this procedure and of the standard direct Jaffé test were compared, the latter were significantly higher. Unlike the Jaffé method, the present method of determining creatinine is rapid (about 10 min per test), subject to few or no interfering substances, and requires no serum deproteinization.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1157307

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  18 in total

1.  Measurement of serum creatinine--current status and future goals.

Authors:  Michael Peake; Malcolm Whiting
Journal:  Clin Biochem Rev       Date:  2006-11

2.  Modification of Jaffe's kinetic method decreases bilirubin interference: A preliminary report.

Authors:  R Vaishya; Sarika Arora; B Singh; V Mallika
Journal:  Indian J Clin Biochem       Date:  2010-02-10

3.  The effects of cold water immersion after rugby training on muscle power and biochemical markers.

Authors:  Masaki Takeda; Takashi Sato; Tatsushi Hasegawa; Hiroto Shintaku; Hisashi Kato; Yoshihiko Yamaguchi; Zsolt Radak
Journal:  J Sports Sci Med       Date:  2014-09-01       Impact factor: 2.988

4.  Creatinine estimation and interference.

Authors:  Kirtimaan Syal; Dibyajyoti Banerjee; Anand Srinivasan
Journal:  Indian J Clin Biochem       Date:  2013-01-26

Review 5.  Use of serum creatinine concentrations to determine renal function.

Authors:  T D Bjornsson
Journal:  Clin Pharmacokinet       Date:  1979 May-Jun       Impact factor: 6.447

6.  Safety, Tolerability, and Pharmacokinetics of Liposomal Amphotericin B in Immunocompromised Pediatric Patients.

Authors:  Nita L Seibel; Aziza T Shad; Ihor Bekersky; Andreas H Groll; Corina Gonzalez; Lauren V Wood; Paul Jarosinski; Donald Buell; William W Hope; Thomas J Walsh
Journal:  Antimicrob Agents Chemother       Date:  2017-01-24       Impact factor: 5.191

7.  Analysis of serum creatinine using an immobilized enzyme nylon tube reactor incorporating a four-enzyme system.

Authors:  R Ginman; J S Colliss
Journal:  Appl Biochem Biotechnol       Date:  1983-08       Impact factor: 2.926

8.  The use of an immobilized enzyme nylon tube reactor incorporating a four enzyme system for creatinine analysis.

Authors:  R Ginman; J S Colliss; J M Knox
Journal:  Appl Biochem Biotechnol       Date:  1983-06       Impact factor: 2.926

9.  Twenty-four-hour blood pressure profile, orthostatic hypotension, and cardiac dysautonomia in elderly type 2 diabetic hypertensive patients.

Authors:  Alfredo Costa; Daniele Bosone; Matteo Cotta Ramusino; Natascia Ghiotto; Elena Guaschino; Annalisa Zoppi; Angela D'Angelo; Roberto Fogari
Journal:  Clin Auton Res       Date:  2016-09-13       Impact factor: 4.435

10.  Effects of interferents on the kinetic Jaffé reaction and an enzymatic colorimetric test for serum creatinine concentration determination in cats, cows, dogs and horses.

Authors:  R M Jacobs; J H Lumsden; J A Taylor; E Grift
Journal:  Can J Vet Res       Date:  1991-04       Impact factor: 1.310