Literature DB >> 11572901

Tenckhoff catheters post-renal transplantation: the 'pull' technique?

I M Quiroga1, R Baboo, R H Lord, C R Darby.   

Abstract

BACKGROUND: Tenckhoff catheters are used widely for the provision of continuous ambulatory peritoneal dialysis. Traditionally these catheters are removed surgically under anaesthesia. We set out to introduce and monitor prospectively a technique for removal of the Tenckhoff catheter by a 'pull' technique. The intention was to avoid the discomfort, risk and cost of traditional surgery.
METHODS: Over a 1-year period all renal transplant patients having their Tenckhoff catheter removed by this technique were monitored prospectively. All patients were followed for a minimum 2-year period after removal. In the pull technique steady non-jerky traction is applied to the catheter. Complications such as catheter breakage and cuff related sepsis were recorded.
RESULTS: Sepsis related to a retained cuff occurred in only one patient early in the series. There were no other complications. The procedure was well tolerated. Use of local anaesthesia used initially, was largely phased out over the course of study and the procedure moved from the theatre to the ward.
CONCLUSIONS: The pull technique is safe and well tolerated. The technique has significant advantages in selected patients without a history of recent peritonitis or exit site infection, in reducing risk to the patients, the pain of abdominal wall surgery and reduced usage of costly theatre time and in-patient beds.

Entities:  

Mesh:

Year:  2001        PMID: 11572901     DOI: 10.1093/ndt/16.10.2079

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  2 in total

Review 1.  Pull technique versus open surgical removal of the catheter for peritoneal dialysis: a retrospective cohort study.

Authors:  Qi Ding; Bo Zhang; Min Liu; Xiaoyu Li; Lili Zuo
Journal:  Clin Exp Nephrol       Date:  2022-04-15       Impact factor: 2.617

2.  Three cases of retained cuff related infection after manual pull removal of peritoneal dialysis catheter.

Authors:  Suojian Zhang; Xu Zhang; Haitao Li; Zhiqiang Wei; Juan Cao
Journal:  Ren Fail       Date:  2021-12       Impact factor: 2.606

  2 in total