Literature DB >> 11572509

Dental color standards: shade tab arrangement.

R D Paravina1, J M Powers, R M Fay.   

Abstract

PURPOSE: The aim of this study was to analyze the shade tab arrangement of two popular dental shade guides, suggest possible improvements, and propose clinical guidelines.
MATERIALS AND METHODS: Data were recorded using a colorimeter set to standard illuminant source C and CIE L*a*b* system. The manufacturers' shade tab arrangement as well as the possible improvements in the arrangement of shade tabs of Vitapan Classical and Vitapan 3-D Master (Vita Zahnfabrik, Bad Säckingen, Germany) shade guides were examined by regression analysis.
RESULTS: Certain shortcomings in the manufacturers' arrangement of both color standards were observed. The Vitapan 3-D Master arrangement was more consistent, but with a decrease in lightness, tab saturation decreased as well in four of its five groups. When Vitapan Classical and Vitapan 3-D Master tabs were arranged according to deltaE* in relation to the lightest tab, r2 was 0.98 and 0.96, respectively. After dividing the total deltaE* range into four equal segments for the newly established Vitapan Classical guide, r2 was 0.91, 0.95, 0.68, and 0.94, respectively. Corresponding r2 values for Vitapan 3-D Master were 0.96, 0.94, 0.90, 0.94, and 1.0. CLINICAL SIGNIFICANCE: Total color difference in relation to the lightest tab, followed by the tab division into an adequate number of groups, is recommended as a possible and universally applicable mode of tab arrangement in dental color standards.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11572509     DOI: 10.1111/j.1708-8240.2001.tb00271.x

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  5 in total

1.  Spectrophotometric evaluation of a novel aesthetic composite resin with respect to different backgrounds in vitro.

Authors:  Andreas Braun; Alexander Glockmann; Felix Krause
Journal:  Odontology       Date:  2011-12-30       Impact factor: 2.634

2.  Coverage error of three conceptually different shade guide systems to vital unrestored dentition.

Authors:  Funda Bayindir; Shanglun Kuo; William M Johnston; Alvin G Wee
Journal:  J Prosthet Dent       Date:  2007-09       Impact factor: 3.426

3.  Development of a model shade guide for primary teeth.

Authors:  R D Paravina; G Majkic; J R Stalker; S Kiat-Amnuay; J W Chen
Journal:  Eur Arch Paediatr Dent       Date:  2008-06

4.  Identifying the tooth shade in group of patients using Vita Easyshade.

Authors:  Habab Osman Elamin; Neamat Hassan Abubakr; Yahia Eltayib Ibrahim
Journal:  Eur J Dent       Date:  2015 Apr-Jun

5.  New insights in the reproducibility of visual and electronic tooth color assessment for dental practice.

Authors:  Anja Ratzmann; Alexander Welk; Stephanie Hoppe; Jochen Fanghaenel; Christian Schwahn
Journal:  Head Face Med       Date:  2020-12-16       Impact factor: 2.151

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.