Literature DB >> 11571683

Cleaning and disinfection practices in digestive endoscopy in spain: results of a national survey.

E Brullet1, J A Ramirez-Armengol, R Campo.   

Abstract

BACKGROUND AND STUDY AIMS: Disinfection and surveillance of it are important for ensuring safety in gastrointestinal endoscopy. The aim of this survey was to assess the current status of disinfection in gastrointestinal endoscopy units in Spain.
MATERIALS AND METHODS: An anonymous questionnaire on cleaning and disinfection methods was sent to gastrointestinal endoscopy units at 244 public hospitals in Spain. A minimum standard of disinfection (MSD) was defined to evaluate the appropriateness of disinfection practices.
RESULTS: A total of 144 centers responded (58 %). All units perform manual washing of endoscopes before disinfection. Automatic washers are available in only 23 % of the centers. Selective cleaning of internal channels is systematically performed in 85 % of the centers. Glutaraldehyde-based disinfectants are the most commonly employed (84 % of units). The time of exposure to the disinfectant is at least 10 min in 97 % of units, but 20 min or more in only 36 % of them. Endoscopic accessories are sterilized in 57 % of centers. The MSD was complied with by 79 % of the units evaluated. Compliance with the MSD was significantly lower in small units (P = 0.0005) performing small numbers of examinations per month. Quality control tests on the efficacy of disinfection methods are conducted at 66 % of the centers. Specialized personnel record disinfection procedures in 85 % of the centers and supervise them in 55 % of the centers. Half of the units have inadequate equipment and facilities.
CONCLUSIONS: This survey suggests that cleaning and disinfection practices in gastrointestinal endoscopy units in Spain have improved in recent years, and that there is a good compliance with standard guidelines. Most units should improve their equipment and facilities in order to provide better comfort and safety for patients and staff.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11571683     DOI: 10.1055/s-2001-17330

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  4 in total

1.  Current GI endoscope disinfection and QA practices.

Authors:  Frank M Moses; Jennifer S Lee
Journal:  Dig Dis Sci       Date:  2004 Nov-Dec       Impact factor: 3.199

2.  Precautionary practices of healthcare workers who disinfect medical and dental devices using high-level disinfectants.

Authors:  Scott A Henn; James M Boiano; Andrea L Steege
Journal:  Infect Control Hosp Epidemiol       Date:  2015-02       Impact factor: 3.254

3.  Survey of endoscope reprocessing in Korea.

Authors:  Jeong Bae Park; Jae Nam Yang; Yun Jeong Lim; Ja Seol Koo; Jae Young Jang; Sang Hoon Park; Su Jin Hong; Sang-Woo Kim; Hoon Jai Chun
Journal:  Clin Endosc       Date:  2015-01-31

4.  Recent update of gastrointestinal endoscope reprocessing.

Authors:  Kyong Hee Hong; Yun Jeong Lim
Journal:  Clin Endosc       Date:  2013-05-31
  4 in total