Literature DB >> 11569567

Blind trials of an onsite saliva drug test for marijuana and opiates.

A Jehanli1, S Brannan, L Moore, V R Spiehler.   

Abstract

The objective of these clinical trials was to calculate the performance, limit of detection, specificity and sensitivity of a novel, semi-quantitative immunoassay for drugs of abuse in saliva and to determine operator bias when measured blind by four different operators. The test is based on lateral flow gold particle technology coupled with digital photography to provide a semi-quantitative end point. The performance of the test was compared with that of enzyme immunoassays and GC/MS methods. Volunteers consumed marijuana or codeine and their saliva was collected 0.25 to 24 h later with the Cozart RapiScan collection device. The sensitivity and specificity of the opiate test were both 100%+/-10.4% for codeine for 9 h after dosing. The cutoff of the marijuana test at 10 ng/mL THCA was too high to detect marijuana use for more than a few hours after smoking. There was no operator bias because the results were presented in written form either as "positive" or "negative" for each of the five drug classes on the screen of the hand-held reader.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11569567

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  6 in total

Review 1.  Human cannabinoid pharmacokinetics.

Authors:  Marilyn A Huestis
Journal:  Chem Biodivers       Date:  2007-08       Impact factor: 2.408

2.  Vicarious exposure to terrorist attacks and substance use: results from an urban household survey.

Authors:  Adam M Lippert; Michael Fendrich; Timothy P Johnson
Journal:  J Urban Health       Date:  2008-03-25       Impact factor: 3.671

3.  Spot tests: past and present.

Authors:  María Teresa Doménech-Carbó; Antonio Doménech-Carbó
Journal:  ChemTexts       Date:  2021-12-27

Review 4.  Oral fluid testing for drugs of abuse.

Authors:  Wendy M Bosker; Marilyn A Huestis
Journal:  Clin Chem       Date:  2009-09-10       Impact factor: 8.327

Review 5.  Quantitative Lateral Flow Assays for Salivary Biomarker Assessment: A Review.

Authors:  Olga Miočević; Craig R Cole; Mary J Laughlin; Robert L Buck; Paul D Slowey; Elizabeth A Shirtcliff
Journal:  Front Public Health       Date:  2017-06-14

Review 6.  Roadside Drug Testing Approaches.

Authors:  Manal A Alhefeiti; James Barker; Iltaf Shah
Journal:  Molecules       Date:  2021-05-29       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.