| Literature DB >> 11569565 |
D L Duewer1, M C Kline, J W Redman, P J Newall, D J Reeder.
Abstract
The Mixed Stain Study 1 (MSS1, Apr.-Nov. 1997) and Mixed Stain Study 2 (MSS2, Jan.-May 1999) evaluated multiplexed short-tandem repeat (STR) DNA typing systems with samples containing DNA from more than one source. These interlaboratory challenge studies evaluated forensic STR measurement, interpretation, and reporting practice using well-characterized samples of very different analytical difficulty. None of the relatively few errors reported in either exercise resulted in a false identification of a reference source; several errors in evaluating the unknown source in three-source samples would hinder matching the profile in any archival database. None of the measurement anomalies reported is associated with any particular STR multiplex; all DNA amplification anomalies are associated with inefficient DNA extraction, inaccurate DNA quantitation, and/or analytical threshold policies.Entities:
Mesh:
Year: 2001 PMID: 11569565
Source DB: PubMed Journal: J Forensic Sci ISSN: 0022-1198 Impact factor: 1.832