Literature DB >> 11568324

Changes in myometrial and junctional zone thickness and signal intensity: demonstration with kinematic T2-weighted MR imaging.

T Masui1, M Katayama, S Kobayashi, S Nakayama, A Nozaki, H Kabasawa, T Ito, H Sakahara.   

Abstract

PURPOSE: To demonstrate uterine contractions by evaluating changes during time in the thickness of the myometrium and junctional zone and in signal intensity of the uterus with T2-weighted fast magnetic resonance (MR) images in a kinematic fashion.
MATERIALS AND METHODS: Sagittal MR imaging was performed with T2-weighted fast spin-echo (FSE) and multiphase-multisection single-shot FSE (SSFSE) in 60 premenopausal patients during free breathing. SSFSE MR images were evaluated with cine display. The pattern of uterine contractions and changes in signal intensities of the uterine structures were evaluated. Thickness of both myometrium and junctional zone, and their signal intensities, were measured during 15 phases of SSFSE and FSE MR imaging.
RESULTS: Slow-massive (mean, 55%), middle-cycle (mean, 80%), and fine (mean, 93%) contractions were observed. Shape of junctional zones dynamically changed during time, showing focal (mean, 58%) and diffuse (mean, 82%) thickening and wavelike motions (mean, 88%). Ratio of thickness of the myometrium to junctional zone with FSE MR imaging was not significantly different from the mean ratio during 15 phases of SSFSE MR imaging, although maximum percentage of change of the ratio during 15 phases was 42.5%-56.8%. The signal intensities of the myometrium (97%) and junctional zone (75%) changed during time.
CONCLUSION: Kinematic T2-weighted SSFSE MR images demonstrate uterine contractions related to dynamic changes in thickness and signal intensities of the myometrium and junctional zone, and these findings might affect the diagnosis of uterine disease.

Entities:  

Mesh:

Year:  2001        PMID: 11568324     DOI: 10.1148/radiol.2211001390

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  A thickened or indistinct junctional zone on T2-weighted MR images in patients with endometrial carcinoma: pathologic consideration based on microcirculation.

Authors:  Yumiko Oishi Tanaka; Masato Nishida; Hajime Tsunoda; Yoshihito Ichikawa; Yukihisa Saida; Yuji Itai
Journal:  Eur Radiol       Date:  2003-01-25       Impact factor: 5.315

Review 2.  Uterine anatomy and function on cine magnetic resonance imaging.

Authors:  Aki Kido; Kaori Togashi
Journal:  Reprod Med Biol       Date:  2016-02-13

Review 3.  MRI and Adenomyosis: What Can Radiologists Evaluate?

Authors:  Veronica Celli; Miriam Dolciami; Roberta Ninkova; Giada Ercolani; Stefania Rizzo; Maria Grazia Porpora; Carlo Catalano; Lucia Manganaro
Journal:  Int J Environ Res Public Health       Date:  2022-05-11       Impact factor: 4.614

4.  [Role of magnetic resonance imaging (MRI) in establishing the indication for, planning, and following up uterine artery embolization (UAE) for treating symptomatic leiomyomas of the uterus].

Authors:  T J Kröncke; B Hamm
Journal:  Radiologe       Date:  2003-08       Impact factor: 0.635

Review 5.  The Impact of Adenomyosis on Women's Fertility.

Authors:  Tasuku Harada; Yin Mon Khine; Apostolos Kaponis; Theocharis Nikellis; George Decavalas; Fuminori Taniguchi
Journal:  Obstet Gynecol Surv       Date:  2016-09       Impact factor: 2.347

6.  A Layer of Decreased Apparent Diffusion Coefficient at the Endometrial-Myometrial Junction in Uterine Adenomyosis.

Authors:  Aki Kido; Koji Fujimoto; Naoko Matsubara; Masako Kataoka; Ikuo Konishi; Kaori Togashi
Journal:  Magn Reson Med Sci       Date:  2015-11-25       Impact factor: 2.471

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.