Literature DB >> 11568115

Use of up-converting phosphor reporters in lateral-flow assays to detect specific nucleic acid sequences: a rapid, sensitive DNA test to identify human papillomavirus type 16 infection.

P Corstjens1, M Zuiderwijk, A Brink, S Li, H Feindt, R S Niedbala, H Tanke.   

Abstract

BACKGROUND: A lateral-flow (LF) device using the new reporter up-converting phosphor technology (UPT) was applied to DNA (hybridization) assays for the detection of specific nucleic acid sequences, thereby aiming to perform the test outside well-equipped laboratories. The methodology reported here is sensitive and provides a rapid alternative for more elaborate gel electrophoresis and Southern blotting. In a preliminary study, it was applied to screen for the presence of human papillomavirus type 16 (HPV16) in a defined series of cervical carcinomas.
METHODS: A LF assay was used to capture haptenized DNA molecules and hybrids, which were immunolabeled (before LF) with 400-nm UPT particles. These particles emit visible light after excitation with infrared in a process called up-conversion. Because up-conversion occurs in only the phosphor lattice, autofluorescence of other assay components is virtually nonexistent.
RESULTS: The use of the UPT reporter in LF-DNA tests, as compared with colloidal gold, improved the detection limit at least 100-fold. UPT LF-DNA tests were successfully applied to detect (in a blind test) the presence of HPV16 in DNA extracts obtained from cervical carcinomas. Test results matched 100% with previous characterization of these carcinomas.
CONCLUSIONS: The use of UPT in LF assays to detect specific nucleic acids provides low attamole-range sensitivity. Hybridization and consecutive detection of PCR-amplified HPV16 sequences were successful in a background of 10 microg of fish-sperm DNA. The sensitivity of UPT detection in these complex mixtures indicates that detection of viral infections without PCR or other amplification technique is achievable.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11568115

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  33 in total

Review 1.  Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.

Authors:  Christine F Markwalter; Andrew G Kantor; Carson P Moore; Kelly A Richardson; David W Wright
Journal:  Chem Rev       Date:  2018-12-04       Impact factor: 60.622

Review 2.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

3.  Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum.

Authors:  Paul L A M Corstjens; Lisette van Lieshout; Michel Zuiderwijk; Dieuwke Kornelis; Hans J Tanke; Andre M Deelder; Govert J van Dam
Journal:  J Clin Microbiol       Date:  2007-10-17       Impact factor: 5.948

4.  A user-friendly, highly sensitive assay to detect the IFN-gamma secretion by T cells.

Authors:  Paul L A M Corstjens; Michel Zuiderwijk; Hans J Tanke; Jolien J van der Ploeg-van Schip; Tom H M Ottenhoff; Annemiek Geluk
Journal:  Clin Biochem       Date:  2008-01-03       Impact factor: 3.281

Review 5.  Optical imaging-guided cancer therapy with fluorescent nanoparticles.

Authors:  Shan Jiang; Muthu Kumara Gnanasammandhan; Yong Zhang
Journal:  J R Soc Interface       Date:  2009-09-16       Impact factor: 4.118

6.  Plasmonic enhanced emissions from cubic NaYF(4):Yb: Er/Tm nanophosphors.

Authors:  L Sudheendra; Volkan Ortalan; Sanchita Dey; Nigel D Browning; I M Kennedy
Journal:  Chem Mater       Date:  2011-06-14       Impact factor: 9.811

Review 7.  Upconversion nanoparticles: design, nanochemistry, and applications in theranostics.

Authors:  Guanying Chen; Hailong Qiu; Paras N Prasad; Xiaoyuan Chen
Journal:  Chem Rev       Date:  2014-03-10       Impact factor: 60.622

8.  Orientational binding modes of reporters in a viral-nanoparticle lateral flow assay.

Authors:  Jinsu Kim; Ryan Poling-Skutvik; João R C Trabuco; Katerina Kourentzi; Richard C Willson; Jacinta C Conrad
Journal:  Analyst       Date:  2016-12-19       Impact factor: 4.616

9.  Lateral flow assay for simultaneous detection of cellular- and humoral immune responses.

Authors:  Paul L A M Corstjens; Claudia J de Dood; Jolien J van der Ploeg-van Schip; Karien C Wiesmeijer; Terhi Riuttamäki; Krista E van Meijgaarden; John S Spencer; Hans J Tanke; Tom H M Ottenhoff; Annemieke Geluk
Journal:  Clin Biochem       Date:  2011-07-06       Impact factor: 3.281

Review 10.  Tools for diagnosis, monitoring and screening of Schistosoma infections utilizing lateral-flow based assays and upconverting phosphor labels.

Authors:  Paul L A M Corstjens; Claudia J De Dood; Dieuwke Kornelis; Elisa M Tjon Kon Fat; R Alan Wilson; Thomas M Kariuki; Ruth K Nyakundi; Philip T Loverde; William R Abrams; Hans J Tanke; Lisette Van Lieshout; André M Deelder; Govert J Van Dam
Journal:  Parasitology       Date:  2014-06-16       Impact factor: 3.234

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.