Literature DB >> 11564241

Prevention of carotid angioplasty-induced bradycardia and hypotension with temporary venous pacemakers.

J S Harrop1, A D Sharan, R P Benitez, R Armonda, J Thomas, R H Rosenwasser.   

Abstract

OBJECTIVE: Carotid angioplasty with stent placement is becoming an established treatment modality for patients with high-risk carotid stenosis. Unlike carotid endarterectomy, angioplasty causes direct mechanical dilation of the stenotic carotid artery and bulb. Stimulation of the sinus baroreceptors induces a reflexive response that consists of increased parasympathetic discharge and inhibition of sympathetic tone, which results in bradycardia and subsequent cardiogenic hypotension.
METHODS: At a single institution, the experience with 43 patients treated from November 1994 to January 2000 with 47 angioplasty and stent procedures for occlusive carotid artery disease was retrospectively reviewed. Prophylactic temporary venous pacemakers were used to prevent hypotension from possible angioplasty-induced bradycardia. Pacemakers were set to capture a heart rate decrease below 60 beats per minute. Variables analyzed included demographics, etiology of disease, side of the lesion, the presence of symptoms, history of coronary artery disease, percent stenosis, type of stent used, number of dilations, pressure of dilation, and angioplasty balloon diameter.
RESULTS: Ten patients were excluded because pacemakers were not used during their angioplasty procedures, and these included three emergencies and a lesion that was unrelated anatomically to the carotid sinus (petrous carotid). The remaining 37 procedures were performed in 33 patients with a mean age of 67 years, and consisted of 17 men, 16 women, 20 right and 17 left-sided lesions. The pacemakers maintained a cardiac rhythm in 23 (62%) of the 37 procedures and in no case did the pacemaker fail to respond when activated. Recurrent (56%; 10 of 18), radiation-induced (78%; 7 of 9), and medically refractory carotid stenosis (67%; 6 of 9) required intraprocedural pacing. Two patients with recurrent stenosis became hypotensive despite the aid of the pacing device but were not symptomatic. Seventy-nine percent (15 of 19) of symptomatic lesions and 57% (8 of 14) of nonsymptomatic lesions required pacing, which was statistically significant (P = 0.049). No patient experienced an operative morbidity or mortality as a consequence of the temporary pacing devices.
CONCLUSION: Angioplasty-induced bradycardia is a common condition, and it is more prevalent in radiation-induced stenosis and with symptomatic lesions. Temporary venous demand pacing is a safe procedure and may prevent life-threatening, baroreceptor-induced hypotension.

Entities:  

Mesh:

Year:  2001        PMID: 11564241     DOI: 10.1097/00006123-200110000-00006

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  9 in total

1.  Spontaneous improvement of persistent ulceration after carotid artery stenting.

Authors:  S Kohyama; K Kazekawa; M Iko; H Aikawa; M Tsutsumi; Y Go; S Nagata; T Kodama; K Nii; S Matsubara; A Tanaka
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

2.  Anatomical study of the external carotid artery and its branches for administration of superselective intra-arterial chemotherapy via the superficial temporal artery.

Authors:  Kazumichi Yonenaga; Iwai Tohnai; Kenji Mitsudo; Yoshiyuki Mori; Hideto Saijo; Toshinori Iwai; Yoshiyuki Yonehara; Yoshihide Ota; Kojun Torigoe; Tsuyoshi Takato
Journal:  Int J Clin Oncol       Date:  2011-05-03       Impact factor: 3.402

3.  Periprocedural monitoring with regional cerebral oxygen saturation in carotid artery stenting.

Authors:  H Kamii; K Sato; Y Matsumoto; E Furui; M Ezura; A Takahashi
Journal:  Interv Neuroradiol       Date:  2007-06-27       Impact factor: 1.610

4.  Ballooning-induced bradycardia during carotid stenting in primary stenosis and restenosis.

Authors:  Giovanni Nano; Ilias Dalainas; Paolo Bianchi; Silvia Stegher; Luciano Bet; Giovanni Malacrida; Domenico G Tealdi
Journal:  Neuroradiology       Date:  2006-05-03       Impact factor: 2.804

5.  Vasopressor use in the critical care unit for treatment of persistent post-carotid artery stent induced hypotension.

Authors:  Mohan Reddi Nandalur; Howard Cooper; Lowell F Satler; Kiran R Nandalur; John R Laird
Journal:  Neurocrit Care       Date:  2007       Impact factor: 3.210

6.  Hemodynamic instability during carotid angioplasty and stenting-relationship of calcified plaque and its characteristics.

Authors:  Jin Sue Jeon; Seung Hun Sheen; Gyojun Hwang
Journal:  Yonsei Med J       Date:  2013-03-01       Impact factor: 2.759

7.  The Prevalence and Factors Contributing to Hemodynamic Depression in Patients Undergoing Carotid Angioplasty and Stenting.

Authors:  Afshin Borhani Haghighi; Safoora Kokabi; Samaneh Yousefi; Mehrdad Emami; Abdolhamid Shariat; Alireza Nikseresht; Nahid Ashjazadeh; Sadegh Izadi; Peyman Petramfar; Maryam Poursadegh; Abbas Rahimi Jaberi; Sajjad Emami; Hamid Agheli; Reza Nemati; Ehsan Yaghoubi; Kaveh Kashani; Majid Panahandeh; Seyed Moslem Heidari-Khormizi; Salvador Cruz-Flores; Randal Edgell
Journal:  J Vasc Interv Neurol       Date:  2015-10

8.  Haemodynamic depression during carotid angioplasty and stenting.

Authors:  Katarzyna Widecka-Ostrowska; Andrzej Modrzejewski; Jarosław Gorący
Journal:  Pol J Radiol       Date:  2010-10

9.  Severe hemodynamic depression after carotid artery stenting: The problem overcome with a transvenous temporary cardiac pacemaker.

Authors:  Masako Fujii; Takeshi Satow; Hiroshi Kodama; Satoshi Horiguchi
Journal:  Surg Neurol Int       Date:  2021-06-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.