Literature DB >> 11562661

Collagen versus gelatin-coated Dacron versus stretch polytetrafluoroethylene in abdominal aortic bifurcation graft surgery: results of a seven-year prospective, randomized multicenter trial.

M Prager1, P Polterauer, H J Böhmig, O Wagner, A Fügl, G Kretschmer, M Plohner, J Nanobashvili, I Huk.   

Abstract

BACKGROUND: A prospective randomized multicenter trial was performed to compare knitted gelatin-coated Dacron bifurcation grafts, knitted collagen-coated Dacron grafts, and stretch polytetrafluoroethylene (PTFE) grafts.
METHODS: Between 1991 and 1998, 315 elective patients were randomized by age, gender, diabetes, runoff, indication (aneurysm, aortoiliac occlusive disease), and nicotine consumption at 3 centers of vascular surgery in Austria. The patients received gelatin-coated Dacron (GEL-D) grafts (n = 109), collagen-coated Dacron (COL-D) grafts (n = 100), or stretch PTFE grafts (n = 106).
RESULTS: No intraoperative deaths occurred. The 30-day mortality was 3%. No difference was found between the 3 graft materials in long-term patency. The primary 5-year patency rates were 92% for GEL-D, 89% for COL-D, and 91% for stretch PTFE (P =.6001). The secondary 5-year patency rates also differed: 97% for GEL-D, 100% for COL-D, and 97% for stretch PTFE (P =.2062). Early occlusions were observed overall in 3% and late occlusions in 5% of patients. When both Dacron grafts were compared collectively with stretch PTFE, a difference was found in infection rate: Dacron 3% (6/209) versus PTFE 0% (0/106); P <.03.
CONCLUSIONS: The bifurcation grafts of all 3 materials were comparable in primary and secondary patency rates, incidence of false aneurysms, and rate of perioperative complications. Graft infections were confined to the 2 Dacron grafts and did not occur in stretch PTFE grafts.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11562661     DOI: 10.1067/msy.2001.115904

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  4 in total

1.  Repair of the torn descending thoracic aorta using the centrifugal pump for partial left heart bypass.

Authors:  Ernest E Moore; Jon M Burch; John B Moore
Journal:  Ann Surg       Date:  2004-07       Impact factor: 12.969

2.  Aortic aneurysm.

Authors:  Atul Mathur; Varun Mohan; Deepak Ameta; Bhardwaj Gaurav; Pradeep Haranahalli
Journal:  J Transl Int Med       Date:  2016-04-14

Review 3.  Bioprinting of freestanding vascular grafts and the regulatory considerations for additively manufactured vascular prostheses.

Authors:  Sara Abdollahi; Joseph Boktor; Narutoshi Hibino
Journal:  Transl Res       Date:  2019-06-03       Impact factor: 7.012

4.  First-in-man results of a novel vascular graft coated with resorbable polymer for aortic reconstructions--a multicenter, non-randomized safety study.

Authors:  Zuhir Halloul; Hartmut Rimpler; Matthias Waliszewski; Norbert Beier; Frank Meyer; Anja Rappe; Angela Fuellert; Joerg Tautenhahn
Journal:  Langenbecks Arch Surg       Date:  2014-04-28       Impact factor: 3.445

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.