Literature DB >> 11561662

Effect of initial joint position on nerve-cuff recordings of muscle afferents in rabbits.

W Jensen1, S M Lawrence, R R Riso, T Sinkjaer.   

Abstract

The objective was to characterize nerve-cuff recordings of muscle afferents to joint rotation over a large part of the physiological joint range. This information is needed to develop control strategies for functional electrical stimulation (FES) systems using muscle afferent signals for sensory feedback. Five acute rabbit experiments were performed. Tripolar cuff electrodes were implanted around the tibial and peroneal divisions of the sciatic nerve in the rabbit's left leg. The electroneurograms (ENG) were recorded during passive ankle rotation, using a ramp-and-hold profile starting at seven different joint positions (excursion = 5 degrees, velocity = 10 degrees/s, initial positions 60 degrees, 70 degrees, 80 degrees, 90 degrees, 100%, 110 , and 120 ). The amplitude of the afferent activity was dependent on the initial joint position. The steady-state sensitivity of both nerve responses increased with increasing joint flexion, whereas the dynamic sensitivity increased initially but then decreased. The results indicate that recordings of the muscle afferents may provide reliable information over only a part of the physiological joint range. Despite this limitation, muscle afferent activity may be useful for motion feedback if the movement to be controlled is within a narrow joint range such as postural sway.

Entities:  

Mesh:

Year:  2001        PMID: 11561662     DOI: 10.1109/7333.948454

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  4 in total

1.  Model-based ankle joint angle tracing by cuff electrode recordings of peroneal and tibial nerves.

Authors:  Chou-Ching K Lin; Ming-Shaung Ju; Hang-Shing Cheng
Journal:  Med Biol Eng Comput       Date:  2007-02-02       Impact factor: 2.602

2.  State-space decoding of primary afferent neuron firing rates.

Authors:  J B Wagenaar; V Ventura; D J Weber
Journal:  J Neural Eng       Date:  2011-01-19       Impact factor: 5.379

3.  An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.

Authors:  Ahnsei Shon; Jun-Uk Chu; Jiuk Jung; Hyungmin Kim; Inchan Youn
Journal:  Sensors (Basel)       Date:  2017-12-21       Impact factor: 3.576

4.  Compact Optical Nerve Cuff Electrode for Simultaneous Neural Activity Monitoring and Optogenetic Stimulation of Peripheral Nerves.

Authors:  Kang-Il Song; Sunghee Estelle Park; Seul Lee; Hyungmin Kim; Soo Hyun Lee; Inchan Youn
Journal:  Sci Rep       Date:  2018-10-23       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.