Abstract

A prospective study was performed on 25 patients (15 women, 10 men) with unstable fractures of the distal radius selectively treated with a dynamic type of external fixation combined with a hydroxyapatite spacer. The fractures ranged from type VI to type VIII according to Frykman's classification. The patients' mean age at surgery was 49 years (range, 19-75 years). The mean follow-up period was 2.5 years, and overall outcome was assessed using Gartland and Werley's demerit point system as modified by Sarmiento. Radial inclination was 26 degrees +/- 4 degrees at the time of reduction and 26 degrees +/- 5 degrees at follow-up, palmar tilt was 9 degrees +/- 2 degrees at reduction and 8 degrees +/- 3 degrees at follow-up, and ulnar variance was 1.4 +/- 0.6 mm at reduction and 2.1 +/- 0.9 mm at follow-up. The mean range of motion at follow-up was 80 degrees +/- 10 degrees in flexion, 80 degrees +/- 10 degrees in extension, 85 degrees +/- 10 degrees in supination, and 80 degrees +/- 5 degrees in pronation. The outcome in 24 of 25 patients was evaluated as excellent. In the surgical treatment of unstable fractures of the distal radius using external fixator, the fracture reduction should be supported with bone graft or a bone substitute, and a hydroxyapatite spacer was considered to be a useful substitute for a bone graft.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11561247     DOI: 10.1053/jhsu.2001.27771

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  5 in total

1.  The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures.

Authors:  Michael G Jakubietz; Joerg G Gruenert; Rafael G Jakubietz
Journal:  J Orthop Surg Res       Date:  2011-05-22       Impact factor: 2.359

Review 2.  The use of bone grafts and substitutes in the treatment of distal radius fractures.

Authors:  Kagan Ozer; Kevin C Chung
Journal:  Hand Clin       Date:  2012-03-27       Impact factor: 1.907

3.  [Mechanical failure of porous hydroxyapatite ceramics 7.5 years after implantation in the proximal tibial].

Authors:  W Linhart; D Briem; M Amling; J M Rueger; J Windolf
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

4.  The Unstable Distal Radius Fracture-How Do We Define It? A Systematic Review.

Authors:  Monique M J Walenkamp; Lara M Vos; Simon D Strackee; J Carel Goslings; Niels W L Schep
Journal:  J Wrist Surg       Date:  2015-11

5.  Percutaneous upper extremity fracture fixation using a novel glass-based adhesive.

Authors:  Paul Zalzal; Oleg Safir; Adel Alhalawani; Marcello Papini; Mark Towler
Journal:  J Orthop       Date:  2018-01-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.