Bileaflet aortic valve prosthesis pivot geometry influences platelet secretion and anionic phospholipid exposure.

B R Travis1, U M Marzec, H L Leo, T Momin, C Sanders, S R Hanson, A P Yoganathan.   

Abstract

The clinical histories of the Medtronic Parallel (MP) and St. Jude Medical (SJM) Standard valves suggest pivot geometry influences the thrombogenic characteristics of bileaflet prostheses. This work studied the effects of various pivot geometries on markers of platelet damage in a controlled, in vitro apparatus. The Medtronic Parallel valve, two St. Jude Medical valves, and two demonstration prostheses were used to study the effects of bileaflet pivot design, gap width, and size on platelet secretion and anionic phospholipid expression during leakage flow. A centrifugal pump was used to drive blood through a circuit containing a bileaflet prosthesis. Samples were taken at set time intervals after the start of the pump. These samples were analyzed by cell counting, flow cytometry, and enzyme-linked immunosorbant assay. No significant differences were observed in platelet secretion or anionic phospholipid expression between experiments with the SJM 27 Standard regular leaker, the SJM 20 regular leaker, and the MP 27 valves. Significant differences in platelet secretion and anionic phospholipid expression were observed between a SJM 27 Standard regular leaker and a SJM 27 high leaker valve. These studies suggest that leakage gap width within bileaflet valve pivots has a significant effect on platelet damage initiated by leakage flow.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11556722     DOI: 10.1114/1.1385808

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  7 in total

1.  Effect of hinge gap width of a St. Jude medical bileaflet mechanical heart valve on blood damage potential--an in vitro micro particle image velocimetry study.

Authors:  Brian H Jun; Neelakantan Saikrishnan; Sivakkumar Arjunon; B Min Yun; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2014-09       Impact factor: 2.097

2.  Numerical investigation of the performance of three hinge designs of bileaflet mechanical heart valves.

Authors:  Hélène A Simon; Liang Ge; Fotis Sotiropoulos; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2010-06-23       Impact factor: 3.934

3.  High-shear stress sensitizes platelets to subsequent low-shear conditions.

Authors:  Jawaad Sheriff; Danny Bluestein; Gaurav Girdhar; Jolyon Jesty
Journal:  Ann Biomed Eng       Date:  2010-02-05       Impact factor: 3.934

Review 4.  Simulation of Mechanical Heart Valve Dysfunction and the Non-Newtonian Blood Model Approach.

Authors:  Aolin Chen; Adi Azriff Bin Basri; Norzian Bin Ismail; Masaaki Tamagawa; Di Zhu; Kamarul Arifin Ahmad
Journal:  Appl Bionics Biomech       Date:  2022-04-19       Impact factor: 1.664

5.  Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices.

Authors:  Danny Bluestein; Gaurav Girdhar; Shmuel Einav; Marvin J Slepian
Journal:  J Biomech       Date:  2012-12-06       Impact factor: 2.712

Review 6.  Fluid mechanics of artificial heart valves.

Authors:  Lakshmi P Dasi; Helene A Simon; Philippe Sucosky; Ajit P Yoganathan
Journal:  Clin Exp Pharmacol Physiol       Date:  2009-02       Impact factor: 2.557

7.  Micro particle image velocimetry measurements of steady diastolic leakage flow in the hinge of a St. Jude Medical® regent™ mechanical heart valve.

Authors:  Brian H Jun; Neelakantan Saikrishnan; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2013-10-02       Impact factor: 3.934

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.