Literature DB >> 1155568

Optic disk topography and visual field defects in patients with increased intraocular pressure.

H D Hoskins, E C Gelber.   

Abstract

One hundred one eyes of 54 ocular hypertensive patients were studied to determine the value of optic disk evaluation in predicting the presence or absence and the location and type of visual field defects by means of binocular slit-lamp examination and projected 35-mm monocular color slides. We suspected visual field loss erroneously in only one patient, and failed to detect ten (16%) of 61 eyes with field defects. An examiner experienced in slit-lamp evaluation of the optic disk can accurately predict the presence, absence, and location of field defects in most cases by stereoscopic evaluation of disk topography.

Entities:  

Mesh:

Year:  1975        PMID: 1155568     DOI: 10.1016/0002-9394(75)90146-4

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  12 in total

1.  Changing concepts of primary open-angle glaucoma and early detection.

Authors:  R N Battista; P Huston; M W Davis
Journal:  Can Fam Physician       Date:  1986-07       Impact factor: 3.275

2.  Variability of expert observers in evaluating the optic disc.

Authors:  P R Lichter
Journal:  Trans Am Ophthalmol Soc       Date:  1976

3.  Physician recognition of ophthalmoscopic signs of open-angle glaucoma: effect of an educational program.

Authors:  K L Margolis; B E Money; L A Kopietz; E C Rich
Journal:  J Gen Intern Med       Date:  1989 Jul-Aug       Impact factor: 5.128

4.  Correlation of pattern discrimination perimetry to the optic disc and visual field in ocular hypertensive and chronic open-angle glaucoma patients.

Authors:  W C Stewart; A B Connor; G M Rogers
Journal:  Int Ophthalmol       Date:  1995       Impact factor: 2.031

5.  Glaucoma screening by means of an optic disc grid.

Authors:  R A Hitchings; D B Brown; S A Anderton
Journal:  Br J Ophthalmol       Date:  1983-06       Impact factor: 4.638

6.  An optic disc grid: its evaluation in reproducibility studies on the cup/disc ratio.

Authors:  R A Hitchings; C Genio; S Anderton; P Clark
Journal:  Br J Ophthalmol       Date:  1983-06       Impact factor: 4.638

7.  Biometric study of the disc cup in open-angle glaucoma.

Authors:  P Betz; F Camps; J Collignon-Brach; G Lavergne; R Weekers
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1982       Impact factor: 3.117

8.  The optic disc in glaucoma, III: diffuse optic disc pallor with raised intraocular pressure.

Authors:  R A Hitchings
Journal:  Br J Ophthalmol       Date:  1978-10       Impact factor: 4.638

9.  The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility.

Authors:  Vassilios P Kozobolis; Eleftherios I Paschalis; Nikitas C Foudoulakis; Stavrenia C Koukoula; Georgios Labiris
Journal:  Clin Ophthalmol       Date:  2010-09-07

10.  Evaluating optic nerve damage: pearls and pitfalls.

Authors:  Paul J Mackenzie; Frederick S Mikelberg
Journal:  Open Ophthalmol J       Date:  2009-09-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.