Safety of implantable coronary stents during 1H-magnetic resonance imaging at 1.0 and 1.5 T.

O Strohm1, D Kivelitz, W Gross, J Schulz-Menger, X Liu, B Hamm, R Dietz, M G Friedrich.   

Abstract

The safety of most available implantable intracoronary stents during magnetic resonance imaging (MRI) has not been sufficiently tested. Minor, but possibly clinically significant, increases in temperature have not been excluded. We measured temperature changes of 14 different stents clinically in use or currently tested for release on the world market. Stents were examined in 1.0- and 1.5-T MR scanners with multiple sequences used in routine cardiac and thoracic MRI examinations ("clinical worst case") and after implantation of the stents into the coronary arteries of excised pig hearts (1.5-T scanner only). We used a highly sensitive infrared camera with a thermal resolution of 10 mK and did not see significant heating of any stent during the examinations. We conclude that MRI is safe in patients with the currently available intracoronary stents.

Entities:  

Mesh:

Year:  1999        PMID: 11554385     DOI: 10.3109/10976649909088336

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  5 in total

Review 1.  Cardiovascular magnetic resonance.

Authors:  D Pennell
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

2.  Safety of cardiovascular magnetic resonance in patients with cardiovascular implants and devices.

Authors:  S K Prasad; D J Pennell
Journal:  Heart       Date:  2004-11       Impact factor: 5.994

3.  Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

Authors:  A M den Harder; D Suchá; R W van Hamersvelt; R P J Budde; P A de Jong; A M R Schilham; C Bos; J M P J Breur; T Leiner
Journal:  PLoS One       Date:  2017-01-31       Impact factor: 3.240

4.  Detailing radio frequency heating induced by coronary stents: a 7.0 Tesla magnetic resonance study.

Authors:  Davide Santoro; Lukas Winter; Alexander Müller; Julia Vogt; Wolfgang Renz; Celal Ozerdem; Andreas Grässl; Valeriy Tkachenko; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  PLoS One       Date:  2012-11-21       Impact factor: 3.240

5.  Pediatric cardiovascular interventional devices: effect on CMR images at 1.5 and 3 Tesla.

Authors:  Sarah N Khan; Stanislas Rapacchi; Daniel S Levi; J Paul Finn
Journal:  J Cardiovasc Magn Reson       Date:  2013-06-19       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.