Literature DB >> 11553832

Multi-detector row CT of thoracic disease with emphasis on 3D volume rendering and CT angiography.

L P Lawler1, E K Fishman.   

Abstract

Multi-detector row computed tomography (CT) with three-dimensional (3D) volume rendering provides a unique perspective on thoracic anatomy and disease. Multi-detector row CT allows shorter acquisition times, greater coverage, and superior image resolution. Three-dimensional volume rendering now permits real-time, interactive modification of relative pixel attenuation in an infinite number of planes and projections. In vascular imaging, this technique provides image quality that equals or surpasses that of conventional angiography. Its use has expanded to aid in diagnosis and surgical planning, often obviating conventional or digital angiography and reducing costs. It is reliable in depicting clot and the pulmonary vasculature and may also be used to evaluate thoracic venous anomalies (eg, pulmonary arteriovenous malformations) and to plan therapy. Airway imaging with multi-detector row CT with 3D volume rendering is particularly useful in the planning and follow-up of stent placement. In diffuse lung disease, this technique can increase nodule detection and help differentiate between small nodules and vessels. It is also helpful in imaging the musculoskeletal system and the thoracic cage. Multi-detector row CT with 3D volume rendering has enhanced the conventional roles of thoracic CT and challenged the supremacy of other imaging modalities. It will likely play a leading role in future radiologic research and practice.

Entities:  

Mesh:

Year:  2001        PMID: 11553832     DOI: 10.1148/radiographics.21.5.g01se021257

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  22 in total

1.  Low-contrast detectability in volume rendering: a phantom study on multidetector-row spiral CT data.

Authors:  Hoen-Oh Shin; Christian V Falck; Michael Galanski
Journal:  Eur Radiol       Date:  2003-10-11       Impact factor: 5.315

Review 2.  Contrast-enhanced MDCT of the thorax.

Authors:  A F Kopp; A Küttner; T Trabold; M Heuschmid; S Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 5.315

Review 3.  Cardiac and vascular MDCT: thoracic imaging.

Authors:  Andreas F Kopp; Axel Küttner; Tobias Trabold; Martin Heuschmid; Stephen Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

4.  Multidetector 3D CT of pulmonary embolism of a peripheral intravenous line.

Authors:  Clifford R Weiss; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2005-06

5.  Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children.

Authors:  Dagmar Honnef; Joachim E Wildberger; Marco Das; Christian Hohl; Andreas H Mahnken; Michael Barker; Rolf W Günther; Gundula Staatz
Journal:  Eur Radiol       Date:  2006-04-19       Impact factor: 5.315

6.  Assessment of major aortopulmonary collateral arteries with multidetector-row computed tomography.

Authors:  Eriko Maeda; Masaaki Akahane; Nobuyuki Kato; Naoto Hayashi; Hisao Koga; Haruyasu Yamada; Hitoshi Kato; Kuni Ohtomo
Journal:  Radiat Med       Date:  2006-06

7.  Images of a pulmonary embolus: classic and contemporary.

Authors:  Iain D C Kirkpatrick; Michael P Meyers
Journal:  CMAJ       Date:  2002-09-03       Impact factor: 8.262

8.  Planned pulmonary resection for metastatic pulmonary tumor with video-assisted thoracoscopic surgery using multidetector row angiography.

Authors:  Shunsuke Yamada; Yoshimasa Inoue; Atsushi Suga; Masayuki Iwazaki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-01-12

Review 9.  [Low dose multislice CT in the pediatric patient].

Authors:  A Hojreh; F Kainberger; S Puig
Journal:  Radiologe       Date:  2003-12       Impact factor: 0.635

10.  The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters.

Authors:  Ji Hoon Shin; Ho Kyu Lee; Choong Gon Choi; Dae Chul Suh; Tae Hwan Lim; Weechang Kang
Journal:  Korean J Radiol       Date:  2002 Jan-Mar       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.