Literature DB >> 11552164

A review of 243 errors possible during the fabrication of a removable partial denture: part II.

R W Rudd1, K D Rudd.   

Abstract

In Part II of this series, possible errors 72 through 168, all of which may be committed during the fabrication of a removable partial denture, are presented. Suggestions for avoiding the problems and solutions for correcting them are described.

Mesh:

Substances:

Year:  2001        PMID: 11552164     DOI: 10.1067/mpr.2001.118452

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Effect of pouring time and storage temperature on dimensional stability of casts made from irreversible hydrocolloid.

Authors:  M Farzin; H Panahandeh
Journal:  J Dent (Tehran)       Date:  2010-09-30

2.  The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials.

Authors:  Supneet Singh Wadhwa; Richa Mehta; Nidhi Duggal; Kamlesh Vasudeva
Journal:  Contemp Clin Dent       Date:  2013-07

3.  Determination of Polyetheretherketone (PEEK) mechanical properties as a denture material.

Authors:  Saja A Muhsin; Paul V Hatton; Anthony Johnson; Nuno Sereno; Duncan J Wood
Journal:  Saudi Dent J       Date:  2019-03-13

4.  Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

Authors:  Emir Yuzbasioglu; Hanefi Kurt; Rana Turunc; Halenur Bilir
Journal:  BMC Oral Health       Date:  2014-01-30       Impact factor: 2.757

5.  A new digital denture procedure: a first practitioners appraisal.

Authors:  Guillaume Bonnet; Cindy Batisse; Marion Bessadet; Emmanuel Nicolas; Jean-Luc Veyrune
Journal:  BMC Oral Health       Date:  2017-12-20       Impact factor: 2.757