The lever-coil: a simple, inexpensive sensor for respiratory and cardiac motion in MRI experiments.

K W Fishbein1, P McConville, R G Spencer.   

Abstract

Thoracic and abdominal magnetic resonance imaging studies generally require some type of compensation for respiratory and cardiac motions in order to yield artifact-free images with good signal-to-noise ratio. Most techniques for respiratory compensation require the use of a non-NMR sensing device to monitor the subject's chest motion, while cardiac motion compensation generally requires the use of ECG leads within the magnet. An inductive pickup coil placed on the subject's chest is perhaps the simplest and least expensive means of monitoring respiration in a MR scanner. However, due to inductive coupling between the pickup coil, radio frequency resonator and gradient set, this arrangement often results in both NMR and respiratory signal artifacts and can also present a burn hazard to the subject depending on the placement and orientation of the pickup coil. Moreover, the presence of a pickup coil on the chest can degrade local magnetic field homogeneity and thus degrade image quality. Similar problems arise when ECG leads must be connected to the subject for cardiac monitoring and gating. To preserve the benefits of the simple pickup coil while circumventing these limitations, a "lever-coil" sensor is presented in which a pickup coil is mechanically coupled to the subject but is not located within the resonator or gradient coil. This results in much lower mutual inductance between the pickup coil and the resonator or gradients. The optimization of the geometry of the apparatus is discussed and lever-coil signal traces are shown which demonstrate the sensor's ability to simultaneously detect both respiratory and cardiac motion in mice. Finally, respiratory-gated and cardiac-triggered spin echo images of the rat abdomen and mouse heart are presented to demonstrate the utility of the lever-coil sensor.

Entities:  

Mesh:

Year:  2001        PMID: 11551730     DOI: 10.1016/s0730-725x(01)00403-9

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

Review 1.  Current status of cardiac MRI in small animals.

Authors:  J-P Vallée; M K Ivancevic; D Nguyen; D R Morel; M Jaconi
Journal:  MAGMA       Date:  2004-12-16       Impact factor: 2.310

Review 2.  Magnetic resonance imaging and spectroscopy of the murine cardiovascular system.

Authors:  Ashwin Akki; Ashish Gupta; Robert G Weiss
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-01-04       Impact factor: 4.733

3.  Synchronisation strategies in T2-weighted MR imaging for detection of liver lesions: Application on a nude mouse model.

Authors:  L Baboi; L Milot; C Lartizien; C Roche; J-Y Scoazec; F Pilleul; O Beuf
Journal:  Biomed Imaging Interv J       Date:  2007-10-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.