Literature DB >> 11551726

Magnetic resonance imaging of alternating electric currents.

U Mikac1, F Demsar, K Beravs, I Sersa.   

Abstract

Electric Current Density Imaging (CDI) is a new modality of magnetic resonance imaging that enables electric current distribution imaging in conductive samples containing water. So far, two CDI techniques have been in use: DC-CDI operating at zero frequency and RF-CDI operating at the RF Larmor frequency. In this paper we present a new CDI technique, which extends the CDI frequency range to alternating electric currents (AC-CDI). First, a theoretical model for the electric current response to the alternating voltage is presented. Later, this model is used for the frequency analysis of the AC-CDI sequence. Additionally, the effect of off-resonance spins and imperfect refocusing RF pulses on the stability of the AC-CDI sequence and the echo formation is studied. The new theory is verified by experiments on a model system and compared to the other two methods: DC-CDI and RF-CDI. Finally, an application of the AC-CDI sequence to biological systems is demonstrated by an experiment on a wood twig in which an increase of approximately 30% was obtained at AC as compared to DC electric current.

Entities:  

Mesh:

Year:  2001        PMID: 11551726     DOI: 10.1016/s0730-725x(01)00393-9

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Magnetic resonance imaging of oscillating electrical currents.

Authors:  Nicholas W Halpern-Manners; Vikram S Bajaj; Thomas Z Teisseyre; Alexander Pines
Journal:  Proc Natl Acad Sci U S A       Date:  2010-04-26       Impact factor: 11.205

2.  Fast imaging for magnetic resonance electrical impedance tomography.

Authors:  Mark J Hamamura; L Tugan Muftuler
Journal:  Magn Reson Imaging       Date:  2008-05-21       Impact factor: 2.546

3.  MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

Authors:  V E Arpinar; M J Hamamura; E Degirmenci; L T Muftuler
Journal:  Phys Med Biol       Date:  2012-06-08       Impact factor: 3.609

4.  Current density imaging sequence for monitoring current distribution during delivery of electric pulses in irreversible electroporation.

Authors:  Igor Serša; Matej Kranjc; Damijan Miklavčič
Journal:  Biomed Eng Online       Date:  2015-08-27       Impact factor: 2.819

5.  Electric Current Detection Based on the MR Signal Magnitude Decay.

Authors:  Igor Serša
Journal:  Magn Reson Med       Date:  2022-05-05       Impact factor: 3.737

6.  Clinical and economic evaluation of modulated electrohyperthermia concurrent to dose-dense temozolomide 21/28 days regimen in the treatment of recurrent glioblastoma: a retrospective analysis of a two-centre German cohort trial with systematic comparison and effect-to-treatment analysis.

Authors:  Sergey V Roussakow
Journal:  BMJ Open       Date:  2017-11-03       Impact factor: 2.692

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.