The use of renal Doppler ultrasonography to diagnose patent ductus arteriosus in preterm infants.

D L Armstrong1, R L Teele, C A Kuschel, J E Harding.   

Abstract

OBJECTIVE: To prospectively study the diagnostic usefulness of altered renal waveforms in patent ductus arteriosus.
METHODS: We studied preterm infants undergoing echocardiography for a suspected patent ductus arteriosus. A spectral Doppler display was acquired for both renal arteries, and a resistive index was obtained. Sensitivity, specificity, and likelihood ratios were calculated using a clinically significant patent ductus arteriosus (>1.5-mm diameter on color Doppler ultrasonography) as the standard of reference.
RESULTS: Fifty infants had 78 scans. A significant patent ductus arteriosus was present on 39 scans. When the renal resistive index was greater than 1.0, the likelihood ratio for a significant patent ductus arteriosus was 24.8 (specificity, 97.2%; SD, 3.8%). When the renal resistive index was 1.0 or less, the likelihood ratio for a significant patent ductus arteriosus was 0.2 (sensitivity, 77.2%; SD, 9.4%).
CONCLUSIONS: Renal resistive index measurement is a simple investigation that can predict a significant patent ductus arteriosus in patients without congenital heart disease or other causes of diastolic runoff when echocardiography is unavailable.

Entities:  

Mesh:

Year:  2001        PMID: 11549148     DOI: 10.7863/jum.2001.20.9.1005

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  2 in total

Review 1.  Pediatric applications of abdominal vascular Doppler: Part II.

Authors:  Brian D Coley
Journal:  Pediatr Radiol       Date:  2004-08-05

2.  Doppler manifestations of ductal steal: role in decision making.

Authors:  Arvind Sehgal; Huyenthao Tran; Elizabeth Carse
Journal:  Eur J Pediatr       Date:  2010-12-04       Impact factor: 3.183

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.