Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations.

T D Bohm1, F A Mourtada, R K Das.   

Abstract

Studies of intravascular brachytherapy to prevent restenosis following angioplasty have shown many promising results. Accurate dose rate tables based on detailed models of the brachytherapy sources are necessary for treatment planning. This work will present an away and along dose rate table for a 27 mm long catheter based 32P beta source. MD-55-2 radiochromic film has been exposed at five different depths (0.5 mm-4 mm) in a polystyrene phantom using a 27 mm long Guidant 32P beta source. The total dose to the active region of the film was determined using the absolute detector response of the MD-55-2 radiochromic film. The Monte Carlo code MCNP4B2 was also used to calculate the dose to the active region of the film using a detailed model of the source, encapsulation, and radiochromic film. The dose to film calculations showed good agreement with the measurements presented in this work with an average difference of 7%. The Monte Carlo calculations were also verified against previously published depth dose in water measurements determined using radiochromic film and plastic scintillator. The depth dose calculations in water showed good agreement with the previously published measurements with the calculations being about 2.5% lower than the film measurements and about 2.5% higher than the scintillator measurements. This work then uses the verified Monte Carlo code to present a dose rate table for the 32P intravascular beta source.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11548948     DOI: 10.1118/1.1384459

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Monte Carlo dosimetric parameter study of a new (32)P brachytherapy source.

Authors:  Junxiang Wu; Jing Huang; Fengxiang Long; Chengkai Wang; Zhangwen Wu; Chengjun Gou
Journal:  Br J Radiol       Date:  2016-04-04       Impact factor: 3.039

Review 2.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

3.  Wire or coated balloon? Searching for an optimal source for intravascular brachytherapy with beta emitters using (32)P as an example.

Authors:  J Lehmann; C R King
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.