Literature DB >> 11547538

Heart rate variability and hemodynamic alterations in canines with normal cardiac function during exposure to pressure support, continuous positive airway pressure, and a combination of pressure support and continuous positive airway pressure.

S K Frazier1, D K Moser, K S Stone.   

Abstract

Variations in intrathoracic pressure generated by different ventilator weaning modes may significantly affect intrathoracic hemodynamics and cardiovascular stability. Although several investigators have attributed cardiovascular alterations during ventilator weaning to augmented sympathetic tone, there is limited investigation of changes in autonomic tone during ventilator weaning. Heart rate variability (HRV), the analysis of beat-to-beat changes in heart rate, is a noninvasive indicator of autonomic tone that might be useful in the identification of patients who are at risk for weaning difficulty due to underlying cardiac dysfunction. The authors describe HRV and hemodynamics in response to 3 ventilatory conditions: pressure support (PS) 10 cmH2O, continuous positive airway pressure (CPAP) 10 cmH2O, and a combination of PS 10 cmH2O and CPAP 10 cmH2O (PS + CPAP) in a group of canines with normal ventricular function. Six canines were studied in the laboratory. Continuous 3-lead electrocardiographic data were collected during baseline (controlled mechanical ventilation) and following transition to each of the ventilatory conditions (PS, CPAP, PS + CPAP) for analysis of HRV. HRV was evaluated using power spectral analysis to define the power under the curve in a very low frequency range (0.0033 to < 0.04 Hz, sympathetic tone), a low frequency range (0.04 to < 0.15 Hz, primarily sympathetic tone), and a high frequency range (0.15 to < 0.40 Hz, parasympathetic tone). A thermodilution pulmonary artery catheter measured cardiac output and right ventricular end-diastolic volume to describe global hemodynamics. There were significant increases in very low frequency power (sympathetic tone) with a concomitant significant reduction in high-frequency power (parasympathetic tone) with exposure to PS + CPAP. These alterations in HRV were associated with significantly increased heart rate and reduced right ventricular end-diastolic volume. Although there was a small but significant increase in cardiac output with exposure to PS, HRV was unchanged. These data indicate that there was a relative shift in autonomic balance to increased sympathetic and decreased parasympathetic tone with exposure to PS + CPAP. The increase in intrathoracic pressure reduced right ventricular end-diastolic volume (preload). This hemodynamic alteration generated a change in autonomic tone, so that cardiac output could be maintained. Individuals with autonomic and/or cardiovascular dysfunction may not be capable of this type of response and may fail to successfully wean from mechanical ventilation.

Entities:  

Mesh:

Year:  2001        PMID: 11547538     DOI: 10.1177/109980040100200302

Source DB:  PubMed          Journal:  Biol Res Nurs        ISSN: 1099-8004            Impact factor:   2.522


  6 in total

Review 1.  Influence of Spontaneous and Mechanical Ventilation on Frequency-Based Measures of Heart Rate Variability.

Authors:  Khlood Bubshait; Yasmine Alabbasi
Journal:  Crit Care Res Pract       Date:  2021-12-26

2.  Animal models in genomic research: Techniques, applications, and roles for nurses.

Authors:  Nicole D Osier; Lan Pham; Amanda Savarese; Kendra Sayles; Sheila A Alexander
Journal:  Appl Nurs Res       Date:  2016-08-22       Impact factor: 2.257

3.  Failed weaning from mechanical ventilation and cardiac dysfunction.

Authors:  Jahan Porhomayon; Peter Papadakos; Nader D Nader
Journal:  Crit Care Res Pract       Date:  2012-09-06

4.  Changes in the heart rate variability in patients with obstructive sleep apnea and its response to acute CPAP treatment.

Authors:  Ernesto Kufoy; Jose-Alberto Palma; Jon Lopez; Manuel Alegre; Elena Urrestarazu; Julio Artieda; Jorge Iriarte
Journal:  PLoS One       Date:  2012-03-16       Impact factor: 3.240

5.  Application of heart-rate variability in patients undergoing weaning from mechanical ventilation.

Authors:  Chun-Ta Huang; Yi-Ju Tsai; Jou-Wei Lin; Sheng-Yuan Ruan; Huey-Dong Wu; Chong-Jen Yu
Journal:  Crit Care       Date:  2014-01-23       Impact factor: 9.097

6.  Acute application of bilevel positive airway pressure influences the cardiac autonomic nervous system.

Authors:  Camila Bianca Falasco Pantoni; Renata Gonçalves Mendes; Luciana Di Thommazo; Aparecida Maria Catai; Luciana Maria Malosá Sampaio; Audrey Borghi-Silva
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.