Literature DB >> 11547382

Dissociation of modular total hip arthroplasty at the femoral head-neck interface after loosening of the acetabular shell following hip dislocation.

C M Chu1, S J Wang, L C Lin.   

Abstract

Modular component dissociation is a potential problem of current modular total hip arthroplasty (THA) systems. We describe a case of dissociation of the modular THA at the femoral head-neck interface after loosening of the acetabular shell during closed reduction for posterior dislocation of THA. The causes of this dissociation and acetabular shell loosening are discussed. Successful treatment was provided with surgical revision of the acetabular and the femoral head components. The present case serves as a graphic reminder that the acetabular shell overhanging the acetabular bone must be avoided when implanting modular THA components.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11547382     DOI: 10.1054/arth.2001.24448

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Fracture of a modular femoral neck after total hip arthroplasty: a case report.

Authors:  Geoffrey Wright; Scott Sporer; Robert Urban; Joshua Jacobs
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

2.  Early intraprosthetic dislocation of a total hip replacement with dual mobility socket: clinical presentation and update review.

Authors:  François Loubignac; Emmanuel Felts; Raphaël Allal
Journal:  Eur J Orthop Surg Traumatol       Date:  2011-11-08

3.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

Review 4.  Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component.

Authors:  Keith A Fehring; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2015-06-19       Impact factor: 4.176

5.  Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

Authors:  A Kouzelis; C S Georgiou; P Megas
Journal:  J Orthop Traumatol       Date:  2011-12-08

6.  Late Nontraumatic Dissociation of the Femoral Head and Trunnion in a Total Hip Arthroplasty.

Authors:  Simon J M Parker; Wasim Khan; Simon Mellor
Journal:  Case Rep Orthop       Date:  2015-05-11

7.  Atraumatic dissociation of a modular shoulder hemiarthroplasty: a case report and literature review.

Authors:  Marlon M Mencia; Raakesh Goalan; Rondell Skeete
Journal:  JSES Int       Date:  2020-04-08

8.  Spontaneous Dissociation of Anatomic Medullary Locking A Plus (AML A Plus) Femoral Component at the Head-Neck Interface.

Authors:  Ketan Pande; Juzaily Fekry Leong; Ngai Nung Lo
Journal:  J Orthop Case Rep       Date:  2015 Jul-Sep
  8 in total