Literature DB >> 11547043

CT pulmonary angiography with a macromolecular contrast medium: a comparative study versus iobitridol in rabbits.

M Wiart1, C Corot, Y Berthezene, X Violas, E Canet.   

Abstract

RATIONALE AND
OBJECTIVES: To compare the pharmacokinetics of a new macromolecular iodinated contrast medium, prototype P743, with a standard contrast agent (iobitridol) for spiral computed tomography pulmonary angiography in rabbits.
METHODS: Manual injection was first used to test the performance of P743 even in cases of nonoptimal bolus timing. Then a protocol was designed to compare vessel enhancement in both first-pass and delayed scans for the two contrast agents with the help of a power injector.
RESULTS: With manual fast injection, the first pass of iobitridol was observed only on proximal scans. Conversely, opacification of vessels was maintained during three spiral scans with P743 under the same injection conditions. When optimal bolus timing was performed, higher vessel enhancement was observed during bolus first pass with iobitridol (iodine dosage 250 mg I/kg) compared with P743 (150 mg I/kg). However, during the postbolus phase, the decrease in attenuation values was markedly faster with iobitridol than with P743.
CONCLUSIONS: This study confirmed that P743 remains more intravascular than iobitridol, which may have clinical implications for the diagnosis of pulmonary embolism, for example.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11547043     DOI: 10.1097/00004424-200109000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

1.  Early modifications of hepatic perfusion measured by functional CT in a rat model of hepatocellular carcinoma using a blood pool contrast agent.

Authors:  Laure S Fournier; Charles Andre Cuenod; Cedric de Bazelaire; Nathalie Siauve; Christophe Rosty; Phuong Lan Tran; Guy Frija; Olivier Clement
Journal:  Eur Radiol       Date:  2004-07-29       Impact factor: 5.315

2.  Imaging of pulmonary embolism and t-PA therapy effects using MDCT and liposomal iohexol blood pool agent: preliminary results in a rabbit model.

Authors:  Stephen J Burke; Ananth Annapragada; Eric A Hoffman; Emmanuel Chen; Ketan B Ghaghada; Jered Sieren; Edwin J R van Beek
Journal:  Acad Radiol       Date:  2007-03       Impact factor: 3.173

3.  Morphologic changes of mammary carcinomas in mice over time as monitored by flat-panel detector volume computed tomography.

Authors:  Jeannine Missbach-Guentner; Christian Dullin; Sarah Kimmina; Marta Zientkowska; Melanie Domeyer-Missbach; Cordula Malz; Eckhardt Grabbe; Walter Stühmer; Frauke Alves
Journal:  Neoplasia       Date:  2008-07       Impact factor: 5.715

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.