Literature DB >> 11545632

Three-dimensional ultrasound for the measurement of choroidal melanomas.

J M Romero1, P T Finger, R B Rosen, R Iezzi.   

Abstract

OBJECTIVE: To evaluate the reliability of 3-dimensional ultrasound (3D-US) for the measurement of choroidal melanomas.
DESIGN: Retrospective case series. PARTICIPANTS: Forty-two consecutive cases of choroidal melanoma imaged with 3D-US.
METHODS: Tumor measurements obtained with ophthalmoscopy, transillumination, standard ultrasound techniques, 3D-US, and pathological studies. Tumor diameters, heights, and volumes were compared. Our 3D-US tumor measurement techniques were tested for intraobserver and interscan reproducibility.
RESULTS: Fifty 3D-US images were studied. The 3D-US tumor measurements were found to be reproducible (height coefficient of variation [CV] < or = 3%; diameter CV < or = 9.7%; volume CV < or = 13.2%). There was significant correlation with the usual methods of tumor measurement (diameter r = 0.76; height r > or = 0.98). Significant differences were found between measurements at pathological examination, as compared with both 2-dimensional and 3D-US height measurements (range, 0.73-0.83 mm). This finding was thought to be due to specimen shrinkage. Three-dimensional ultrasound was found to be at least as reproducible as clinical examination and standard ultrasound techniques used for measurement of diameter and height of choroidal melanomas. It was our impression that the 3D-US volume measurements accounted for the geometry of the tumor better than volume estimates calculated from basal area and tumor height.
CONCLUSIONS: Three-dimensional ultrasound measurements of choroidal melanoma were reproducible, correlated well with other tumor measurement techniques, and can be used for measurement of choroidal melanomas.

Entities:  

Mesh:

Year:  2001        PMID: 11545632     DOI: 10.1001/archopht.119.9.1275

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  7 in total

1.  Metachronous ispilateral conjunctival then choroidal melanoma.

Authors:  P T Finger; C E Iacob; S A McCormick
Journal:  Br J Ophthalmol       Date:  2006-10       Impact factor: 4.638

Review 2.  A reference standard for the measurement of macular oedema.

Authors:  K A Goatman
Journal:  Br J Ophthalmol       Date:  2006-09       Impact factor: 4.638

3.  In vivo high-frequency, contrast-enhanced ultrasonography of uveal melanoma in mice: imaging features and histopathologic correlations.

Authors:  Qing Zhang; Hua Yang; Shin J Kang; Yanggan Wang; Geoffrey D Wang; Tonya Coulthard; Hans E Grossniklaus
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-01       Impact factor: 4.799

Review 4.  Early anti-VEGF treatment for radiation maculopathy and optic neuropathy: lessons learned.

Authors:  Brittany E Powell; Kimberly J Chin; Paul T Finger
Journal:  Eye (Lond)       Date:  2022-08-16       Impact factor: 4.456

5.  Three dimensional ultrasound of retinoblastoma: initial experience.

Authors:  P T Finger; A Khoobehi; M R Ponce-Contreras; D Della Rocca; J P S Garcia
Journal:  Br J Ophthalmol       Date:  2002-10       Impact factor: 4.638

6.  Measurement of human choroidal melanoma xenograft volume in rats using high-frequency ultrasound.

Authors:  Rod D Braun; Kerry S Vistisen
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-01       Impact factor: 4.799

7.  Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation.

Authors:  Alena Furdova; Robert Furda; Miron Sramka; Martin Chorvath; Jan Rybar; Pavol Vesely; Jela Valaskova; Vladimir Siska
Journal:  BMC Ophthalmol       Date:  2022-08-05       Impact factor: 2.086

  7 in total