Literature DB >> 11537608

Chlorine injury and the comparative performance of Colisure (TM), ColiLert (TM) and ColiQuik (TM) for the enumeration of coliform bacteria and E.coli in drinking water.

G A McFeters1, B H Pyle, S J Gillis, C J Acomb, D Ferrazza.   

Abstract

Several factors have stimulated interest in recently developed substrate specific media for the detection of coliform bacteria in water. This study compared the performance of Colisure (TM) (Millipore), ColiLert (TM) (Environetics) and ColiQuick (TM) (Hach) with accepted membrane filtration and MPN methodologies for the enumeration of total coliforms and E. coli in chlorinated water. The performance of all three media was compared, in MPN configuration, with LTB/MPN (confirmed) using a variety of drinking and source water samples, both with and without chlorination. The Cochran-Mantel-Haenszel test yielded statistical correlations between results obtained with each of the three new enzyme detection media and accepted reference methods for the detection of low numbers of total coliforms. Another series of tests compared the performance of Colisure with accepted methods (LTB/MPN confirmed with BGLB and EC-MUG) in the detection of total coliforms and E. coli in sewage-spiked samples simulating contaminated drinking water, using an USEPA/AWWA test protocol. The results demonstrated that Colisure detected these indicator bacteria with greater sensitivity than the accepted methods and that this difference increased between 24 and 28 hours of incubation. The results of this study collectively support the validity of the new enzyme detection method for the detection of low levels of coliform bacteria and E. coli in source water and contaminated drinking water.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 11537608

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  3 in total

1.  A rapid, direct method for enumerating respiring enterohemorrhagic Escherichia coli O157:H7 in water.

Authors:  B H Pyle; S C Broadaway; G A McFeters
Journal:  Appl Environ Microbiol       Date:  1995-07       Impact factor: 4.792

2.  Development of Fluorescence In Situ Hybridization as a Rapid, Accurate Method for Detecting Coliforms in Water Samples.

Authors:  Jong-Tar Kuo; Li-Li Chang; Chia-Yuan Yen; Teh-Hua Tsai; Yu-Chi Chang; Yu-Tang Huang; Ying-Chien Chung
Journal:  Biosensors (Basel)       Date:  2020-12-24

3.  Massive microbiological groundwater contamination associated with a waterborne outbreak in Lake Erie, South Bass Island, Ohio.

Authors:  Theng-Theng Fong; Linda S Mansfield; David L Wilson; David J Schwab; Stephanie L Molloy; Joan B Rose
Journal:  Environ Health Perspect       Date:  2007-02-06       Impact factor: 9.031

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.