Literature DB >> 11535475

Topography-driven excimer laser for the retreatment of decentralized myopic photorefractive keratectomy.

G Alessio1, F Boscia, M G La Tegola, C Sborgia.   

Abstract

OBJECTIVE: This study evaluated the efficacy, predictability, stability, and safety of a software program (Corneal Interactive Programmed Topographic Ablation, CIPTA, LIGI, Taranto, Italy), which, by transferring programmed ablation from the corneal topograph to a flying-spot excimer laser, provides customized laser ablation for correction of postmyopic photorefractive keratectomy (PRK) decentrations.
DESIGN: Noncomparative consecutive case series. PARTICIPANTS: Thirty-two eyes of 32 subjects with a mean age of 35 years (range, 19-49; standard deviation [SD], 7.9) had CIPTA-guided PRK at the Clinica Oculistica of Bari University (Italy). All the subjects had irregular astigmatism after postmyopic PRK because of clinically significant, decentered treatments of more than 1 mm. OPERATION: Individual topographies were acquired by a corneal topograph (Orbscan II, Orbtek, Inc., Salt Lake City, UT). These, together with refractive data, were processed to obtain a customized altimetric ablation profile that was transferred to a flying-spot laser (Laserscan 2000, Lasersight, Orlando, FL). MAIN OUTCOME MEASURES: The topographic study of centration and data on uncorrected (UCVA) and best-corrected (BCVA) visual acuity, predictability, and stability of refraction, and any complications, were analyzed.
RESULTS: Mean follow-up was 10.3 months (range, 4-18 months; SD, 5.8). At the last postoperative examination, 29 eyes (90.6%) had a UCVA superior to 20/40. Nineteen eyes (59.4%) had a UCVA of 20/20. Twenty-two eyes (68.75%) were within 0.50 diopters (D) of attempted correction in the spherical equivalent and 28 eyes (87.5%) were within 1 D. The index of success of astigmatic correction was 0.15. No eye lost Snellen lines of BCVA, whereas 18 eyes (56.25%) gained Snellen lines. Postoperative topographies revealed well-centered treatments.
CONCLUSIONS: The combination of topographic data with computer controlled flying-spot excimer laser ablation is a suitable solution for correcting irregular astigmatism after postmyopic PRK decentrations.

Entities:  

Mesh:

Year:  2001        PMID: 11535475     DOI: 10.1016/s0161-6420(01)00706-0

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  11 in total

1.  A clinical follow up of PRK and LASIK in eyes with preoperative abnormal corneal topographies.

Authors:  P Schor; S M C Beer; O da Silva; R Takahashi; M Campos
Journal:  Br J Ophthalmol       Date:  2003-06       Impact factor: 4.638

2.  Visual outcomes of topography-guided excimer laser surgery for treatment of patients with irregular astigmatism.

Authors:  Mohammad Ghoreishi; Afsaneh Naderi Beni; Zahra Naderi Beni
Journal:  Lasers Med Sci       Date:  2013-02-24       Impact factor: 3.161

3.  Analysis of Age, Gender, and Refractive Error-Related Changes of the Anterior Corneal Surface Parameters Using Oculus Keratograph Topography.

Authors:  Nasrin Moghadas Sharif; Negareh Yazdani; Leila Shahkarami; Hadi Ostadi Moghaddam; Asieh Ehsaei
Journal:  J Curr Ophthalmol       Date:  2020-07-04

4.  One-step transepithelial topography-guided ablation in the treatment of myopic astigmatism.

Authors:  Aleksandar Stojanovic; Shihao Chen; Xiangjun Chen; Filip Stojanovic; Jia Zhang; Ting Zhang; Tor Paaske Utheim
Journal:  PLoS One       Date:  2013-06-17       Impact factor: 3.240

5.  Evaluation of the shape symmetry of bilateral normal corneas in a Chinese population.

Authors:  Fangjun Bao; Hao Chen; Ye Yu; Jiguo Yu; Shi Zhou; Jing Wang; QinMei Wang; Ahmed Elsheikh
Journal:  PLoS One       Date:  2013-08-29       Impact factor: 3.240

6.  Geometrical custom modeling of human cornea in vivo and its use for the diagnosis of corneal ectasia.

Authors:  Francisco Cavas-Martínez; Daniel G Fernández-Pacheco; Ernesto De la Cruz-Sánchez; José Nieto Martínez; Francisco J Fernández Cañavate; Alfredo Vega-Estrada; Ana B Plaza-Puche; Jorge L Alió
Journal:  PLoS One       Date:  2014-10-17       Impact factor: 3.240

7.  Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK.

Authors:  XiaoBo Zheng; WeiHua Yang; LiFang Huang; JunJie Wang; Si Cao; Brendan Geraghty; YiPing Zhao; QinMei Wang; FangJun Bao; Ahmed Elsheikh
Journal:  Sci Rep       Date:  2017-06-09       Impact factor: 4.379

8.  Customized laser vision correction for irregular cornea post-refractive surgery.

Authors:  Rohit Shetty; Vaitheeshwaran Ganesan Lalgudi; Luci Kaweri; Urvija Choudhary; Aishwariya Chabra; Krati Gupta; Pooja Khamar
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

9.  Topography-guided custom ablation treatment for treatment of keratoconus.

Authors:  Rohit Shetty; Sharon D'Souza; Samaresh Srivastava; R Ashwini
Journal:  Indian J Ophthalmol       Date:  2013-08       Impact factor: 1.848

10.  Effect of Misalignment between Successive Corneal Videokeratography Maps on the Repeatability of Topography Data.

Authors:  FangJun Bao; JunJie Wang; JinHai Huang; Ye Yu; ManLi Deng; LinNa Li; Ayong Yu; QinMei Wang; Pinakin Gunvant Davey; Ahmed Elsheikh
Journal:  PLoS One       Date:  2015-11-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.