Literature DB >> 11533641

Direct and sensitive detection of a human virus by rupture event scanning.

M A Cooper1, F N Dultsev, T Minson, V P Ostanin, C Abell, D Klenerman.   

Abstract

We have developed a sensitive, economical method that directly detects viruses by making use of the interaction between type 1 herpes simplex virus (HSV1) and specific antibodies covalently attached to the oscillating surface of a quartz crystal microbalance (QCM). The virions were detached from the surface by monotonously increasing the amplitude of oscillation of the QCM, while using the QCM to sensitively detect the acoustic noise produced when the interactions were broken. We term this process rupture event scanning (REVS). The method is quantitative over at least six orders of magnitude, and its sensitivity approaches detection of a single virus particle.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11533641     DOI: 10.1038/nbt0901-833

Source DB:  PubMed          Journal:  Nat Biotechnol        ISSN: 1087-0156            Impact factor:   54.908


  15 in total

1.  Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA.

Authors:  Chunhai Fan; Kevin W Plaxco; Alan J Heeger
Journal:  Proc Natl Acad Sci U S A       Date:  2003-07-16       Impact factor: 11.205

2.  Effect of molecular crowding on the response of an electrochemical DNA sensor.

Authors:  Francesco Ricci; Rebecca Y Lai; Alan J Heeger; Kevin W Plaxco; James J Sumner
Journal:  Langmuir       Date:  2007-05-09       Impact factor: 3.882

Review 3.  Studying Soft Interfaces with Shear Waves: Principles and Applications of the Quartz Crystal Microbalance (QCM).

Authors:  Diethelm Johannsmann; Arne Langhoff; Christian Leppin
Journal:  Sensors (Basel)       Date:  2021-05-17       Impact factor: 3.576

4.  Detecting protein-ligand binding on supported bilayers by local pH modulation.

Authors:  Hyunsook Jung; Aaron D Robison; Paul S Cremer
Journal:  J Am Chem Soc       Date:  2009-01-28       Impact factor: 15.419

5.  Real-time Recognition of Mycobacterium tuberculosis and Lipoarabinomannan using the Quartz Crystal Microbalance.

Authors:  Leslie A Hiatt; David E Cliffel
Journal:  Sens Actuators B Chem       Date:  2012-08-19       Impact factor: 7.460

6.  Study on pivot-point vibration of molecular bond-rupture events by quartz crystal microbalance for biomedical diagnostics.

Authors:  Yong J Yuan; Renjie Jia
Journal:  Int J Nanomedicine       Date:  2012-01-24

7.  Nanoplasmonic biosensor for rapid detection of multiple viral variants in human serum.

Authors:  Nikhil Bhalla; Amir Farokh Payam; Alessio Morelli; Preetam Kumar Sharma; Rhiannon Johnson; Alan Thomson; Pawan Jolly; Francesco Canfarotta
Journal:  Sens Actuators B Chem       Date:  2022-04-18       Impact factor: 9.221

8.  Magnetically assisted DNA assays: high selectivity using conjugated polymers for amplified fluorescent transduction.

Authors:  Hui Xu; Haiping Wu; Fei Huang; Shiping Song; Wenxin Li; Yong Cao; Chunhai Fan
Journal:  Nucleic Acids Res       Date:  2005-05-19       Impact factor: 16.971

Review 9.  Potential diagnostic applications of biosensors: current and future directions.

Authors:  Shiping Song; Hui Xu; Chunhai Fan
Journal:  Int J Nanomedicine       Date:  2006

10.  Improving defences at the portal of HIV entry: mucosal and innate immunity.

Authors:  Robin J Shattock; Barton F Haynes; Bali Pulendran; Jorge Flores; José Esparza
Journal:  PLoS Med       Date:  2008-04-01       Impact factor: 11.069

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.