Carr-Purcell sequences with composite pulses.

M D Hürlimann1.   

Abstract

We present novel Carr-Purcell-like sequences using composite pulses that exhibit improved performance in strongly inhomogeneous fields. The sequences are designed to retain the intrinsic error correction of the standard Carr-Purcell-Meiboom-Gill (CPMG) sequence. This is achieved by matching the excitation pulse with the refocusing cycle such that the initial transverse magnetization lies along the axis n(Beta) characterizing the overall rotation of the refocusing cycle. Such sequences are suitable for relaxation measurements. It is shown that in sufficiently inhomogeneous fields, the echo amplitudes have an initial transient modulation that is limited to the first few echoes and then decay with the intrinsic relaxation time of the sample. We show different examples of such sequences that are constructed from simple composite pulses. Sequences of the form 90 degrees (0)-(90 degrees (90-theta/2)-theta(180-theta/2)-90 degrees (90-theta/2))(n) with theta approximately 90 degrees and 270 degrees generate signal over a bandwidth larger than that of the conventional CPMG sequence, resulting in an improved signal-to-noise ratio in inhomogeneous fields. The new sequence 127 degrees (x,y)-(127 degrees (x)-127 degrees (-x))(n) only excites signal off-resonance with a spectrum that is bimodal, peaking at Delta omega(0)=+/-omega(1). Depending on the phase and exact timing of the first pulse, symmetric or antisymmetric excitation is obtained. We also demonstrate several new sequences with improved dependence on the RF field strength. The sequence (22.5 degrees (67.5)-90 degrees (-22.5))-(90 degrees (67.5)-45 degrees (157.5)-90 degrees (67.5))(n) has the property that the phase of the signal depends on B(1), allowing coarse B(1) imaging in a one-dimensional experiment. Copyright 2001 Academic Press.

Entities:  

Mesh:

Year:  2001        PMID: 11531370     DOI: 10.1006/jmre.2001.2370

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  2 in total

1.  T₂ -weighted MRI of post-infarct myocardial edema in mice.

Authors:  Ronald J Beyers; R Scott Smith; Yaqin Xu; Bryan A Piras; Michael Salerno; Stuart S Berr; Craig H Meyer; Christopher M Kramer; Brent A French; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

2.  Optimized, unequal pulse spacing in multiple echo sequences improves refocusing in magnetic resonance.

Authors:  Elizabeth R Jenista; Ashley M Stokes; Rosa Tamara Branca; Warren S Warren
Journal:  J Chem Phys       Date:  2009-11-28       Impact factor: 3.488

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.