Development of a personal monitoring method for nitrogen dioxide and sulfur dioxide with Sep-Pak C18 cartridge sampling and ion chromatographic determination.

Y Wang1, A Allen, D Mark, R M Harrison.   

Abstract

Personal monitoring methods for the determination of hourly integrated concentrations of NO2 and SO2 in ambient air have been developed. Triethanolamine (TEA)-impregnated C18 Sep-Pak cartridges were used to collect NO2 and SO2 simultaneously. After sampling, NO2 and SO2 as their nitrite, nitrate, sulfite and sulfate analogues were stripped from the cartridges with a solution of 5% methanol in distilled, deionized water (DDW) and then determined by ion chromatography. Laboratory tests were conducted to evaluate the sampling rate, collection and recovery efficiencies, breakthrough volumes, absorption capacity, interference and sample stability on the cartridge during storage. NO2 and SO2 detection limits of 0.3 and 0.4 ppb respectively for 1 h samples were obtained. Recoveries for both NO2 and SO2 exceeded 85%.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 11529158     DOI: 10.1039/a905305k

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  2 in total

1.  Personal exposure monitoring of particulate matter, nitrogen dioxide, and carbon monoxide, including susceptible groups.

Authors:  R M Harrison; C A Thornton; R G Lawrence; D Mark; R P Kinnersley; J G Ayres
Journal:  Occup Environ Med       Date:  2002-10       Impact factor: 4.402

2.  Scripted drives: A robust protocol for generating exposures to traffic-related air pollution.

Authors:  Allison P Patton; Robert Laumbach; Pamela Ohman-Strickland; Kathy Black; Shahnaz Alimokhtari; Paul Lioy; Howard M Kipen
Journal:  Atmos Environ (1994)       Date:  2016-08-12       Impact factor: 4.798

  2 in total