Literature DB >> 11526573

Strength analysis of Le Fort I osteotomy fixation: titanium versus resorbable plates.

M M Araujo1, P D Waite, J E Lemons.   

Abstract

PURPOSE: The purpose of this study was to compare the biomechanical characteristics of metallic and polymeric fixation systems using a 3-dimensional skull model to simulate clinical conditions of maxillary advancement and loading.
MATERIAL AND METHODS: Standard titanium, prebent titanium, and resorbable plates and mesh were applied to surgically altered polyurethane skulls. The constructs were loaded using an Instron machine (Instron Inc, Canton, MA) in anterior-posterior (AP) and inferior-superior (IS) directions. The load displacement, load to failure, and deformation magnitudes and modes of failure were recorded. Statistical studies included analysis of variance (ANOVA) at P <.05.
RESULTS: Elastic stiffness was different among groups in the AP direction, but no significant difference was found in the IS direction. The IS loading direction load displacement (stiffness) was significantly greater than that on AP loading. The maximum load for permanent deformation was larger in the AP direction, while the maximum load for breaking was larger in the IS direction.
CONCLUSION: The overall evaluation of the model and test analyses supported the relative value of this in vitro system and study procedure. All systems showed load capacity magnitudes above 285 N (64 lbs) and more elastic resistance in the IS direction. The resorbable systems showed lower elastic stiffness compared with the titanium systems, but they appear to be adequate for fixation and withstanding the forces of mastication. Copyright 2001 American Association of Oral and Maxillofacial Surgeons.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11526573     DOI: 10.1053/joms.2001.25832

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  6 in total

1.  Analysis of residual stress and hardness in regions of pre-manufactured and manual bends in fixation plates for maxillary advancement.

Authors:  Marcelo Marotta Araújo; Andrezza Lauria; Marcelo Breno Meneses Mendes; Ana Paula Rosifini Alves Claro; Cristiane Aparecida de Assis Claro; Roger William Fernandes Moreira
Journal:  Oral Maxillofac Surg       Date:  2015-05-06

2.  Use positional screws for Le Fort I osteotomy fixation: technical note.

Authors:  Rafael Linard Avelar; Maykel Sullyvan Marinho de Souza; Eduardo Costa Studart Soares; Rodrygo Nunes Tavares
Journal:  Oral Maxillofac Surg       Date:  2017-05-01

3.  A Modified Technique for Placing Prebent Plates during a Le Fort I Osteotomy: A Technical Note.

Authors:  Marwa Ragaey; Joseph Van Sickels
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2016-08-23

4.  The Tooth Size Discrepancy among Orthodontic Patients and Normal Occlusion Individuals from Saudi Arabia: A Three-Dimensional Scan Analysis of Diagnostic Casts.

Authors:  Abdulaziz Abdullah Alshahrani; Ibrahim Alshahrani; Mohamed Khaled Addas; Sharaz Shaik; Faris Mohammed Binhomran; Jaber AlQahtani
Journal:  Contemp Clin Dent       Date:  2020-08-07

5.  Closure of anterior open bites with mandibular surgery: advantages and disadvantages of this approach.

Authors:  Joseph E Van Sickels; Aaron Wallender
Journal:  Oral Maxillofac Surg       Date:  2012-09-04

6.  To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

Authors:  Rishi K Bali; Parveen Sharma; Shalu Jindal; Shivani Gaba
Journal:  Natl J Maxillofac Surg       Date:  2013-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.