Literature DB >> 11526357

Does stent design affect probability of restenosis? A randomized trial comparing Multilink stents with GFX stents.

Y Yoshitomi1, S Kojima, M Yano, T Sugi, Y Matsumoto, M Saotome, K Tanaka, M Endo, M Kuramochi.   

Abstract

BACKGROUND: Experimental studies have revealed that stent configuration influences intimal hyperplasia. The purpose of this study was to evaluate clinical outcomes for 2 stent designs in a randomized trial with quantitative coronary angiography (QCA) and intravascular ultrasonography (IVUS).
METHODS: We randomly assigned 100 patients with 107 lesions and symptomatic coronary artery disease to deployment of a Multilink stent (Advanced Cardiovascular Systems, Guidant, Santa Clara, Calif) or a GFX stent (Applied Vascular Engineering, Santa Rosa, Calif) with IVUS guidance. QCA and IVUS studies were performed before and after intervention and at follow-up (4.2 +/- 1.0 months).
RESULTS: There were no significant differences in baseline characteristics and QCA and IVUS parameters before and after intervention between the 2 groups. However, minimal lumen diameter at follow-up was significantly larger in the Multilink group (2.46 +/- 0.59 vs 2.08 +/- 0.79 mm, P <.05). Maximal in-stent intimal hyperplasia was significantly larger in the GFX group (2.9 +/- 1.7 vs 1.8 +/- 1.2 mm(2), P <.01). The restenosis rate differed between the 2 groups (Multilink 4% vs GFX 26%, P =.003). In multiple stepwise logistic regression analysis, the only predictor that significantly correlated with restenosis was stent type (P <.01). The odds ratio for the GFX stent-treated vessels was 18.65 (95% confidence interval 2.10-165.45).
CONCLUSIONS: With deployment of the GFX stent, a thicker neointima develops within the stent. Stent configuration may affect clinical outcomes.

Entities:  

Mesh:

Year:  2001        PMID: 11526357     DOI: 10.1067/mhj.2001.117321

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  6 in total

Review 1.  Current understanding of coronary in-stent restenosis. Pathophysiology, clinical presentation, diagnostic work-up, and management.

Authors:  T M Schiele
Journal:  Z Kardiol       Date:  2005-11

Review 2.  Drug-eluting stents: the past, present, and future.

Authors:  Gregory Katz; Bhisham Harchandani; Binita Shah
Journal:  Curr Atheroscler Rep       Date:  2015-03       Impact factor: 5.113

3.  [New developments in drug-eluting stents].

Authors:  M Kollum; C Bode
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

4.  Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease.

Authors:  Luciano Maurício de Abreu Filho; Antonio Artur da Cruz Forte; Marcos Kiyoshi Sumita; Desidério Favarato; George Cesar Ximenes Meireles
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

5.  Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening.

Authors:  John F LaDisa; Lars E Olson; Douglas A Hettrick; David C Warltier; Judy R Kersten; Paul S Pagel
Journal:  Biomed Eng Online       Date:  2005-10-26       Impact factor: 2.819

Review 6.  Treatment of coronary in-stent restenosis: a systematic review.

Authors:  Leos Pleva; Pavel Kukla; Ota Hlinomaz
Journal:  J Geriatr Cardiol       Date:  2018-02       Impact factor: 3.327

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.