Literature DB >> 11524199

Changes in measured intraocular pressure after hyperopic photorefractive keratectomy.

R Munger1, A A Dohadwala, W G Hodge, W B Jackson, G Mintsioulis, K F Damji.   

Abstract

PURPOSE: To investigate the effect of hyperopic photorefractive keratectomy (PRK) on intraocular pressure (IOP) measurements.
SETTING: University of Ottawa Eye Institute, Ottawa Hospital, Ottawa, Canada.
METHODS: In this retrospective cohort study, IOP and central corneal thickness (CCT) were measured preoperatively and at 1, 2, 3, 6, 12, 18, and 24 months in 191 eyes that had hyperopic PRK with the VISX Star excimer laser. All corrections applied were between +1.00 and +6.50 diopters (D) of sphere and less than 3.75 D of cylinder.
RESULTS: At all postoperative examinations, the mean IOP in the hyperopic PRK group was 1.0 to 1.8 mm Hg lower than the preoperative IOP (P <.001). A large range of IOP changes was found across the population; eg, at 6 months, 49% of the eyes had a change in IOP from baseline of at least +/-3 mm Hg. A mean reduction of 19 microm of CCT was found with pachymetry after surgery (P < .001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or applied correction. Changes in IOP were strongly correlated with preoperative IOP at all time points and with preoperative CCT at 18 and 24 months (P < .001). After hyperopic PRK, the measured IOP was more likely to increase in patients with preoperative IOPs less than 14.5 mm Hg and more likely to decrease in patients with preoperative IOPs above 14.5 mm Hg.
CONCLUSION: Changes in IOP after hyperopic PRK were similar to changes after myopic PRK, despite only minimal changes in the CCT. This suggests that hyperopic PRK results in biomechanical effects that modify the elastic properties of the cornea beyond the changes in rigidity expected from central corneal thinning. There was a strong negative correlation between the measured preoperative IOP and the change in IOP postoperatively that was likely the result of regression of the mean effect.

Entities:  

Mesh:

Year:  2001        PMID: 11524199     DOI: 10.1016/s0886-3350(01)00971-3

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery.

Authors:  Antonios P Aristeidou; Georgios Labiris; Andreas Katsanos; Michalis Fanariotis; Nikitas C Foudoulakis; Vassilios P Kozobolis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-06-25       Impact factor: 3.117

Review 2.  [Glaucoma diagnostics and corneal thickness].

Authors:  J von Eicken; M Kohlhaas; H Höh
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

Review 3.  Biomechanics and wound healing in the cornea.

Authors:  William J Dupps; Steven E Wilson
Journal:  Exp Eye Res       Date:  2006-05-23       Impact factor: 3.467

4.  Underestimation of intraocular pressure after photorefractive keratectomy: a biomechanical analysis.

Authors:  Per Hallberg; Anders Eklund; Kenneth Santala; Timo Koskela; Olof Lindahl; Christina Lindén
Journal:  Med Biol Eng Comput       Date:  2006-07-26       Impact factor: 2.602

5.  Central corneal thickness does not correlate with TonoLab-measured IOP in several mouse strains with single transgenic mutations of matricellular proteins.

Authors:  Ayan Chatterjee; Dong-Jin Oh; Min Hyung Kang; Douglas J Rhee
Journal:  Exp Eye Res       Date:  2013-06-24       Impact factor: 3.467

6.  Evaluation of corneal hysteresis and corneal resistance factor after corneal cross-linking for keratoconus.

Authors:  Maria Gkika; Georgios Labiris; Athanassios Giarmoukakis; Anna Koutsogianni; Vassilios Kozobolis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-12-22       Impact factor: 3.117

7.  Differences in the early biomechanical effects of hyperopic and myopic laser in situ keratomileusis.

Authors:  Fabricio Witzel de Medeiros; Abhijit Sinha-Roy; Milton Ruiz Alves; Steven E Wilson; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2010-06       Impact factor: 3.351

8.  Surface wave elastometry of the cornea in porcine and human donor eyes.

Authors:  William J Dupps; Marcelo V Netto; Satish Herekar; Ronald R Krueger
Journal:  J Refract Surg       Date:  2007-01       Impact factor: 3.573

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.