Vascular closure devices and the risk of vascular complications after percutaneous coronary intervention in patients receiving glycoprotein IIb-IIIa inhibitors.

F S Resnic1, G J Blake, L Ohno-Machado, A P Selwyn, J J Popma, C Rogers.   

Abstract

Vascular closure devices offer advantages over traditional means of obtaining hemostasis after percutaneous coronary intervention (PCI) in terms of patient comfort and time to ambulation. We investigate whether such devices also reduce the risk of vascular complications in selected patient populations. We conducted a retrospective analysis of all patients who underwent PCI at our institution between January 1998 and December 1999. Of 3,151 consecutive patients, 3,027 were eligible to receive vascular closure devices. Of these, 1,485 received a closure device and 1,409 received glycoprotein IIb-IIIa antagonists. The overall vascular complication rate, as defined by the need for surgical repair or transfusion, or the development of arteriovenous fistula, pseudoaneurysm, or large hematoma, was 4.20%. By univariate analysis, the use of closure devices was associated with a lower vascular complication rate (3.03% vs 5.52%; p = 0.002) and a shorter length of hospital stay (2.77 vs 3.97 days, p <0.001). Multivariate analysis showed a significant reduction in vascular complications with closure devices (odds ratio 0.59, p = 0.007). For the subgroup of patients receiving glycoprotein IIb-IIIa antagonists, the use of closure devices was associated with an even more pronounced reduction in the risk of vascular complications (odds ratio 0.45, p <0.008). Thus, the use of closure devices in selected patients undergoing PCI is associated with a low rate of vascular complications and decreased length of stay. This benefit was most marked for patients receiving glycoprotein IIb-IIIa antagonists.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11524056     DOI: 10.1016/s0002-9149(01)01725-8

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  16 in total

1.  Bleeding complications after contemporary pharmacoinvasive therapy for ST elevation myocardial infarction.

Authors:  Matthew J Gutierrez; Atul Aggarwal; Kristin Gilbert; Burton E Sobel; Harold L Dauerman
Journal:  J Thromb Thrombolysis       Date:  2004-12       Impact factor: 2.300

2.  Use of vascular closure device is safe and effective in electrophysiological procedures.

Authors:  Ilir Maraj; Adam S Budzikowski; Waleed Ali; Crisitina A Mitre; John Kassotis
Journal:  J Interv Card Electrophysiol       Date:  2015-04-29       Impact factor: 1.900

Review 3.  Vascular access and closure in coronary angiography and percutaneous intervention.

Authors:  Robert A Byrne; Salvatore Cassese; Maryam Linhardt; Adnan Kastrati
Journal:  Nat Rev Cardiol       Date:  2012-11-27       Impact factor: 32.419

4.  Access-site complications after rescue percutaneous coronary intervention during thrombolysis for acute myocardial infarction.

Authors:  A Germing; M Lindstaedt; S Ulrich; W Bojara; T Lawo; A Mügge; P Grewe
Journal:  Z Kardiol       Date:  2005-01

5.  Comparison of Exo-Seal(®) and Angio-Seal (®) for arterial puncture site closure: A randomized, multicenter, single-blind trial.

Authors:  Johannes Ketterle; Harald Rittger; Inga Helmig; Lutz Klinghammer; Stefan Zimmermann; Wolfgang Hohenforst-Schmidt; Johannes Brachmann; Holger Nef; Stephan Achenbach; Christian Schlundt
Journal:  Herz       Date:  2015-06-13       Impact factor: 1.443

6.  Large femoral aneurysm as a late complication after vessel closure device application.

Authors:  Alfried Germing; Peter Grewe; Andreas Mügge; Michael Lindstaedt
Journal:  Clin Res Cardiol       Date:  2006-04-03       Impact factor: 5.460

7.  A cost-minimization analysis of the angio-seal vascular closure device following percutaneous coronary intervention.

Authors:  Frederic S Resnic; Nipun Arora; Michael Matheny; Matthew R Reynolds
Journal:  Am J Cardiol       Date:  2007-01-22       Impact factor: 2.778

8.  An evaluation of immediate sheath removal and use of the Angio-Seal vascular closure device in neuroradiological interventions.

Authors:  L Pierot; D Herbreteau; S Bracard; J Berge; C Cognard
Journal:  Neuroradiology       Date:  2005-10-28       Impact factor: 2.804

9.  The frequency of vascular complications associated with the use of vascular closure devices varies by indication for cardiac catheterization.

Authors:  Emilia Stegemann; Rainer Hoffmann; Steven Marso; Berthold Stegemann; Nikolaus Marx; Thomas Lauer
Journal:  Clin Res Cardiol       Date:  2011-04-11       Impact factor: 5.460

10.  Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade.

Authors:  Niels Zorger; Thomas Finkenzeller; Markus Lenhart; Okka Hamer; Christian Paetzel; Inghita Borisch; Ingolf Toepel; Stefan Feuerbach; Johann Link
Journal:  Eur Radiol       Date:  2003-11-11       Impact factor: 5.315

View more