Literature DB >> 11523238

Model TJ-IV computer-assisted vectorcardiogram analysis system.

X Guo1, X Jue, Y Ruan, Z Wang.   

Abstract

During last 16 years we have successfully developed the computer-assisted vectorcardiogram analysis systems: model TJ-I, TJ-II, and TJ-III, but some technical problems remained unresolved, such as the recognition accuracy for vectorcardiograms, measurement of the parameters of complicated QRS waves, the ratio of T loop length to width, and the area of spatial vectors etc. A new system, model TJ-IV was designed to resolve these technical problems. The system was equipped with a 586 computer with a CPU of 120 MHz. Special new low-noise amplifier was employed and C language was used for programming. Three graph recognition techniques were used to enhance the accuracy of VCG recognition. 32 orthogonal electrocardiograms and vectorcardiograms were displayed and printed, and 566 parameters of vectorcardiograms were calculated. Our results with 150 cases showed that the system had high accuracy of graph recognition, and parameter calculation and the results were essentially consistent with those of manipulative methods. We were led to concluded when compared with TJ-III system, the new version has higher accuracy of processing and measurement for vectorcardiograms, is able to process more vectorcardiographic parameters, with higher processing speed.

Mesh:

Year:  2001        PMID: 11523238     DOI: 10.1007/BF02888027

Source DB:  PubMed          Journal:  J Tongji Med Univ        ISSN: 0257-716X


  5 in total

1.  Vectorcardiographic loop alignment and the measurement of morphologic beat-to-beat variability in noisy signals.

Authors:  M Aström; E Carro Santos; L Sörnmo; P Laguna; B Wohlfart
Journal:  IEEE Trans Biomed Eng       Date:  2000-04       Impact factor: 4.538

2.  On-line vectorcardiography during elective coronary angioplasty indicates procedure-related myocardial infarction.

Authors:  J Jensen; S V Eriksson; B Lindvall; P Lundin; C Sylvén
Journal:  Coron Artery Dis       Date:  2000-03       Impact factor: 1.439

3.  Vectorcardiographic evaluation of myocardial infarct size: departure parameters are superior to conventional spatial parameters.

Authors:  Y Watanabe; J Wang; T Kondo; M Tokuda; H Chikamatsu; T Yasui; T Yamaguchi; M Kinoshita; S Kamide; N Nagai; Y Abo; H Yokoi; H Hishida
Journal:  Jpn Circ J       Date:  1998-07

4.  [Location of atrial and ventricular insertions of accessory atrioventricular pathways using surface ECG mapping and its importance in catheter ablation therapy].

Authors:  M Bernadic; R Hatala; W Kaltenbrunner; M Tysler; K Steinbach; I Hulín
Journal:  Bratisl Lek Listy       Date:  1995-04       Impact factor: 1.278

5.  Spatial ventricular gradient in patients with Wolff-Parkinson-White syndrome in comparison with normal subjects: vectorcardiographic evidence for significant repolarization changes due to preexcitation.

Authors:  K Sawada; M Hirai; H Hayashi; F Inaba-Sato; H Sano; T Yanagawa; Y Tomita; H Agetsuma; Y Ichihara; H Saito
Journal:  Intern Med       Date:  1995-08       Impact factor: 1.271

  5 in total
  2 in total

Review 1.  Significance of vectorcardiogram in the cardiological diagnosis of the 21st century.

Authors:  Andrés Ricardo Pérez Riera; Augusto H Uchida; Celso Ferreira Filho; Adriano Meneghini; Celso Ferreira; Edgardo Schapacknik; Sergio Dubner; Paulo Moffa
Journal:  Clin Cardiol       Date:  2007-07       Impact factor: 2.882

2.  Frontal plane vectorcardiograms: theory and graphics visualization of cardiac health status.

Authors:  Dhanjoo N Ghista; U Rajendra Acharya; T Nagenthiran
Journal:  J Med Syst       Date:  2009-02-21       Impact factor: 4.460

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.