Literature DB >> 11519565

Assessment of intraocular foreign bodies by helical-CT multiplanar imaging.

A Papadopoulos1, A Fotinos, V Maniatis, S Kavadias, A Michaelides, M Avouri, C Kalamara, K Stringaris.   

Abstract

The aim of this study was to examine the effectiveness of helical CT in the assessment of intraocular foreign bodies, evaluating two protocols with different collimation. We performed helical-CT studies in 30 patients. Fifteen patients were examined with 1.5-mm collimation and the other 15 patients with 3.0-mm collimation. All other imaging parameters were identical in both protocols. Multiplanar images were reconstructed. The examinations were reviewed for presence, localization and size of intraocular foreign bodies. We compare our results with the surgical data. We estimate the required examination time. In the first group (collimation 1.5 mm) an intraorbital foreign body was detected in 8 of 15 patients. In 3 of 8 patients an intraocular foreign body (all were metallic) was detected. In the second group (collimation 3.0 mm) an intraorbital foreign body was detected in 9 of 15 patients. In 8 of 9 patients an intraocular foreign body (all were metallic) was detected. Our results were confirmed by surgery in all cases. Examination time was 36 s in the first group and 18 s in the second group. Computed tomography should be considered the imaging modality of choice in the assessment of metallic intraocular foreign bodies and 3.0-mm collimation is optional, because of reduced examination time and radiation exposure.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11519565     DOI: 10.1007/s003300100825

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  4 in total

1.  Intraorbital wooden foreign body (IOFB): mimicking air on CT.

Authors:  O O Adesanya; Denise M Dawkins
Journal:  Emerg Radiol       Date:  2007-01-31

Review 2.  Imaging of orbital disorders in pediatric patients.

Authors:  Luis Gorospe; Aránzazu Royo; Teresa Berrocal; Pilar García-Raya; Pilar Moreno; José Abelairas
Journal:  Eur Radiol       Date:  2002-11-19       Impact factor: 5.315

3.  [Accuracy and relevance of CT volumetry in open ocular injuries with intraocular foreign bodies].

Authors:  O A Maneschg; E Volek; Z Lohinai; M D Resch; A Papp; C Korom; K Karlinger; J Németh
Journal:  Ophthalmologe       Date:  2015-04       Impact factor: 1.059

4.  Occult nonmetallic intraocular foreign bodies presenting as fulminant uveitis: a case series and review of the literature.

Authors:  Yevgeniy V Sychev; Elizabeth A Verner-Cole; Eric B Suhler; J Timothy Stout; G Atmaram Vemulakonda
Journal:  Clin Ophthalmol       Date:  2013-09-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.