| Literature DB >> 11516902 |
Abstract
This manuscript reports development and validation of an assay method in rat serum for the simultaneous estimation of C1, C2, and C3, in-house CDRI molecules, of the class of aryloxy-substituted aryl-piperazinyl derivatives. The assay was applied to determine pharmacokinetic data after simultaneous intravenous administration of these three compounds. A high-performance liquid chromatography assay method using isocratic elution and fluorescence (excitation, 250 nm; emission 350 nm) was developed for simultaneous estimation of all the three compounds in rat serum. Linearity was observed between 12.5 and 400 ng/ml for all the three compounds in serum. Recoveries were highly consistent over the concentration ranges for all the analytes. Variations in the intra- and inter-batch accuracy and precision were within the acceptable limits of +/-20% at the limit of quantitation, whereas at higher concentrations it was +/-15%. A mixture of the three compounds was administered intravenously to rats. Blood samples were collected over a period of 6 h and analyzed to determine serum levels and pharmacokinetics of each compound. The pharmacokinetics of the aforementioned three compounds was also determined after individual administration. The results obtained in the N-in-One dosing correlated well with discrete dosing of compounds. Based on the results obtained, C2 emerges to be the compound with appropriate pharmacokinetic parameters. Thus, the N-in-One method is a useful method for increasing the throughput to obtain the pharmacokinetic information.Entities:
Mesh:
Substances:
Year: 2001 PMID: 11516902 DOI: 10.1016/s0731-7085(01)00452-6
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935