Literature DB >> 11516033

Serous fluid leakage following modified Blalock-Taussig operation using PTFE grafts.

M Sahoo1, M Sahu, S Kale, N Saxena.   

Abstract

BACKGROUND: Serous fluid leakage is an unusual but often devastating complication following the placement of a modified Blalock-Taussig shunt using a polytetrafluoroethylene graft. METHOD AND
RESULTS: Between September 1994 and September 1999, out of 268 patients undergoing a modified Blalock-Taussig shunt using polytetrafluoroethylene grafts, 10 developed massive pleural effusion or seroma due to a leak from the surface of the shunt. The age of the patients ranged from 9 days to 7 years. There were 7 males and 3 females. Nine patients presented with respiratory distress between 2 and 12 weeks of shunt surgery and one presented with sudden cardiac arrest. The shunt was patent in all the patients. Initial management was conservative. i.e. by pharmacological means and tube thoracostomy. Reoperation was undertaken in 9 patients when conservative treatment failed. All patients survived except one who had a cardiac arrest before any intervention could be carried out.
CONCLUSIONS: Patients with serous effusion have significant morbidity and mortality and often require reoperation. The initial management remains conservative but, if unsuccessful, re-exploration can be undertaken as it proved to be uniformly successful in our experience.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11516033

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  1 in total

1.  Post Blalock-Taussig shunt mediastinal mass - a single shadow with two different destinies.

Authors:  Manoj Kumar Rohit; Ramalingam Vadivelu; Niranjan Khandelwal; Satheesh Krishna
Journal:  Indian Heart J       Date:  2014-02-22
  1 in total