Literature DB >> 11515888

Experience with spiral computed tomography as the sole diagnostic method for traumatic aortic rupture.

S W Downing1, J S Sperling, S E Mirvis, M G Cardarelli, T B Gilbert, T M Scalea, J S McLaughlin.   

Abstract

BACKGROUND: Spiral computed tomographic (CT) scan is an excellent screen for aortic trauma. Traditionally, aortography is performed when injury is suspected to confirm the diagnosis. We hypothesized that it is safe and expeditious to forgo aortography when the spiral CT demonstrates aortic injury.
METHODS: Retrospective review of 54 patients undergoing aortic repair from July 1994 to December 1999. Spiral CT was the initial diagnostic study in 52 patients. Pseudoaneurysm or aortic wall defect in the presence of mediastinal hematoma was considered diagnostic. Angiography, initially routine, was later performed only when requested by the surgeon, and for all "nonnegative" studies (periaortic hematoma without detectable aortic injury).
RESULTS: Twenty-six patients underwent angiography before operation (group 1). Nineteen group 1 spiral CTs were unequivocally diagnostic; 7 were nonnegative and angiography was required. Twenty-eight other patients underwent repair based on spiral CT alone (group 2). There was one false-positive result in both groups. There were no unexpected operative findings. Mean time from admission to diagnosis was 5.7+/-3.4 hours for group 1 and 1.7+/-1.7 hours for group 2 (p < 0.01).
CONCLUSIONS: Operating on the basis of a diagnostic spiral CT is safe and expeditious. Aortography may be reserved for those with equivocal studies.

Entities:  

Mesh:

Year:  2001        PMID: 11515888     DOI: 10.1016/s0003-4975(01)02827-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  12 in total

1.  Blunt traumatic injury of the ascending aorta: multidetector CT findings in two cases.

Authors:  Scott D Steenburg; James G Ravenel; John S Ikonomidis
Journal:  Emerg Radiol       Date:  2006-11-16

2.  Thoracic aortic and great vessel trauma and its management.

Authors:  Simon J McPherson
Journal:  Semin Intervent Radiol       Date:  2007-06       Impact factor: 1.513

3.  [Endovascular treatment of traumatic ruptures of the thoracic aorta].

Authors:  A Oberhuber; M Thiere; F Simon; M Kramer; T Einsiedel; K-H Orend; L Sunder-Plassmann; H Schelzig
Journal:  Unfallchirurg       Date:  2011-08       Impact factor: 1.000

4.  Current management of traumatic rupture of the descending thoracic aorta.

Authors:  Riyad Karmy-Jones; Nichole Jackson; William Long; Alan Simeone
Journal:  Curr Cardiol Rev       Date:  2009-08

Review 5.  [Diagnosis and immediate therapeutic management of chest trauma. A systematic review of the literature].

Authors:  G Voggenreiter; C Eisold; S Sauerland; U Obertacke
Journal:  Unfallchirurg       Date:  2004-10       Impact factor: 1.000

Review 6.  Diagnosing traumatic rupture of the thoracic aorta in the emergency department.

Authors:  C E O'Conor
Journal:  Emerg Med J       Date:  2004-07       Impact factor: 2.740

7.  Management of traumatic aortic rupture: a 30-year experience.

Authors:  Marcelo G Cardarelli; Joseph S McLaughlin; Stephen W Downing; James M Brown; Safuh Attar; Bartley P Griffith
Journal:  Ann Surg       Date:  2002-10       Impact factor: 12.969

8.  Diagnostic imaging of traumatic pseudoaneurysm of the thoracic aorta.

Authors:  Serif Beslic; Nermina Beslic; Selma Beslic; Amela Sofic; Muris Ibralic; Jasmina Karovic
Journal:  Radiol Oncol       Date:  2010-09-09       Impact factor: 2.991

Review 9.  Computed Tomography Imaging Findings of Acute Aortic Pathologies.

Authors:  Elif S Duran; Farhan Ahmad; Mohamed Elshikh; Irfan Masood; Cihan Duran
Journal:  Cureus       Date:  2019-08-30

10.  Case report: Open replacement of incomplete semi-circular traumatic ruptures of the ascending and descending aorta.

Authors:  Miroslawa Mytsyk; Martin T R Grapow; Jasmin Shahinian; Markus Maurer; Lorenz Gurke; Friedrich S Eckstein
Journal:  J Cardiothorac Surg       Date:  2016-07-16       Impact factor: 1.637