Literature DB >> 11512233

[Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions].

N Holzknecht1, T Helmberger, U J Schoepf, B Ertl-Wagner, C Kulinna, A Stäbler, M Reiser.   

Abstract

PURPOSE: Evaluation of the accuracy of a new electromagnetic target system for interventional CT-guided procedures with virtual navigation in a previously acquired helical CT.
MATERIAL AND METHODS: The new target system CT-Guide 1010 (Ultraguide, Tirat Hacarmel, Israel) for CT-guided interventions was adapted to the video signal of the Somatom Plus 4 and Volume Zoom (Siemens, Erlangen, Germany). A helical CT-dataset including skin-based sensor cubes was transferred to the integrated navigation system inside the scanner room. 50 image-guided interventions and biopsies were performed outside the gantry using virtual navigation to reach the lesion. The accuracy of the procedures was evaluated using documentation of the needle tip with CT-fluoroscopy, results of histology, and follow-up.
RESULTS: The deviation between planned and documented needle tip was 2.2 +/- 2.1 mm in 50 procedures. Time between the end of planning-CT and needle positioning using the system was 13 minutes. There were no complications due to the use of the system.
CONCLUSION: The CT-Guide allows for virtual real-time navigation with high accuracy. Advantages are the free needle angulation without gantry tilt, use of optimal CT perfusion phase for virtual navigation, and reduction of radiation exposure to the patient and interventionalist.

Entities:  

Mesh:

Year:  2001        PMID: 11512233     DOI: 10.1055/s-2001-15841

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  9 in total

Review 1.  Interventional MDCT.

Authors:  Thomas J Vogl; Joern O Balzer; Martin G Mack; Christopher Herzog
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

2.  Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance: a phantom study.

Authors:  Nils Rathmann; Michael Kostrzewa; Kerim Kara; Soenke Bartling; Holger Haubenreisser; Stefan O Schoenberg; Steffen J Diehl
Journal:  Br J Radiol       Date:  2015-09-15       Impact factor: 3.039

3.  Accuracy of biopsy needle navigation using the Medarpa system--computed tomography reality superimposed on the site of intervention.

Authors:  M Fawad Khan; Selami Dogan; Adel Maataoui; Jessen Gurung; Mirko Schiemann; Hanns Ackermann; Stefan Wesarg; Georgios Sakas; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-03-08       Impact factor: 5.315

Review 4.  [Flat-detector CT-based electromagnetic navigation].

Authors:  B C Meyer; K-J Wolf; F K Wacker
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

5.  Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results.

Authors:  Philipp Bruners; Tobias Penzkofer; Markus Nagel; Robert Elfring; Nina Gronloh; Thomas Schmitz-Rode; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2008-11-29       Impact factor: 5.315

6.  Electromagnetic field-based navigation for percutaneous punctures on C-arm CT: experimental evaluation and clinical application.

Authors:  Bernhard C Meyer; Olaf Peter; Markus Nagel; Martin Hoheisel; Bernd B Frericks; Karl-Jürgen Wolf; Frank K Wacker
Journal:  Eur Radiol       Date:  2008-06-11       Impact factor: 5.315

7.  Intermuscular pterygoid-temporal abscess following inferior alveolar nerve block anesthesia-A computer tomography based navigated surgical intervention: Case report and review.

Authors:  Jürgen Wallner; Knut Ernst Reinbacher; Mauro Pau; Matthias Feichtinger
Journal:  Ann Maxillofac Surg       Date:  2014-01

8.  Robotic Assistance System for Cone-Beam Computed Tomography-Guided Percutaneous Needle Placement.

Authors:  Michael Kostrzewa; Andreas Rothfuss; Torben Pätz; Markus Kühne; Stefan O Schoenberg; Steffen J Diehl; Jan Stallkamp; Nils Rathmann
Journal:  Cardiovasc Intervent Radiol       Date:  2021-08-19       Impact factor: 2.740

9.  Puncture accuracy of an optical tracked robotic aiming device-a phantom study.

Authors:  Yannick Scharll; Sofia Letrari; Gregor Laimer; Peter Schullian; Reto Bale
Journal:  Eur Radiol       Date:  2022-06-09       Impact factor: 7.034

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.