Literature DB >> 11511497

Patient and staff dose during CT guided biopsy, drainage and coagulation.

W M Teeuwisse1, J Geleijns, J J Broerse, W R Obermann, E L van Persijn van Meerten.   

Abstract

Patient and staff dose during CT guided coagulation of osteoid osteoma, tissue biopsy and abscess drainage were evaluated retrospectively on a conventional CT scanner and prospectively on a scanner equipped with fluoroscopic CT. The computed tomography dose index (CTDI) and the individual dose equivalent, i.e. the penetrating dose for workers at a depth of 10 mm tissue, were measured. Evaluation of CTDI enabled effective dose and maximum skin entrance doses for the patient to be determined. Doses were assessed for 96 CT guided interventions, including 16 drainages with average effective doses of 13.5 mSv and 9.3 mSv for the conventional CT scanner and the scanner with spiral CT fluoroscopy, respectively, 49 biopsies (effective doses of 8 mSv and 6.1 mSv, respectively), and 31 coagulations of osteoid osteoma (effective doses of 2.1 mSv and 0.8 mSv, respectively). Effective doses to patients were in the same range as those observed for regular diagnostic CT examinations. Entrance skin doses were well below the 2 Gy threshold for deterministic skin effects on the CT scanner equipped with fluoroscopic function (0.03-0.33 Gy), whilst skin doses on the conventional scanner were considerably higher (0.09-1.61 Gy). This is mainly owing to the fact that on the conventional scanner mAs was rarely reduced for scans evaluating needle position whereas low mAs per rotation was selected on the scanner with the fluoroscopy option. The maximum dose to a worker measured outside the lead apron was 28 microSv for one single procedure. The mean dose per procedure was below 10 microSv for radiologists and below 1 microSv for radiographers. Correcting for attenuation of the lead apron, the doses to workers are very low.

Entities:  

Mesh:

Year:  2001        PMID: 11511497     DOI: 10.1259/bjr.74.884.740720

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  22 in total

Review 1.  Interventional MDCT.

Authors:  Thomas J Vogl; Joern O Balzer; Martin G Mack; Christopher Herzog
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

3.  Percutaneous radio-frequency mandibular nerve rhizotomy guided by CT fluoroscopy.

Authors:  S Koizuka; S Saito; K Kubo; A Tomioka; T Takazawa; S Sakurazawa; F Goto
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

4.  Computed tomography fluoroscopy-guided lumbar sympathectomy for a patient with peripheral vascular disease and lumbar spine compression fracture.

Authors:  Masataka Kuroda; Shiro Koizuka; Shigeru Saito; Eri Sato; Daisuke Takizawa; Fumio Goto
Journal:  J Anesth       Date:  2005       Impact factor: 2.078

5.  Newly developed application system for CT-guided puncture based on multidetector row CT without CT fluoroscopy.

Authors:  Toshiyuki Irie; Masashi Kuramochi
Journal:  Radiat Med       Date:  2007-10-26

6.  [Computed tomography guidance: fluoroscopy and more].

Authors:  P M Paprottka; T Helmberger; M F Reiser; C G Trumm
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

7.  Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety.

Authors:  M J Choi; Y Kim; Y S Hong; S S Shim; S M Lim; J K Lee
Journal:  Br J Radiol       Date:  2011-07-26       Impact factor: 3.039

8.  Effect of Body Habitus on Radiation Dose During CT Fluoroscopy-Guided Spine Injections.

Authors:  Ronald J Viola; Giao B Nguyen; Terry T Yoshizumi; Sandra S Stinnett; Jenny K Hoang; Peter G Kranz
Journal:  Interv Neuroradiol       Date:  2014-10-17       Impact factor: 1.610

9.  Flat detector cone beam CT-guided nephrostomy using virtual navigation in patients with iatrogenic ureteral injury.

Authors:  Dechao Jiao; Zongming Li; Zhiguo Li; Shaofeng Shui; Xin-Wei Han
Journal:  Radiol Med       Date:  2017-03-22       Impact factor: 3.469

10.  CT fluoroscopy guided percutaneous gastrostomy or jejunostomy without (CT-PG/PJ) or with simultaneous endoscopy (CT-PEG/PEJ) in otherwise untreatable patients.

Authors:  Fritz W Spelsberg; Ralf-Thorsten Hoffmann; Reinhold A Lang; Hauke Winter; Rolf Weidenhagen; Maximilian Reiser; Karl-Walter Jauch; Christoph Trumm
Journal:  Surg Endosc       Date:  2012-12-12       Impact factor: 4.584

View more