| Literature DB >> 11509298 |
S M Nouraei1, T Pillay, C J Hilton.
Abstract
We report a case of aorto-bronchial fistula 7 years after implantation of a self-expanding metal stent into the left main bronchus. The clinical presentation was characterised by left-sided chest pain, dyspnea and a single bout of haemoptysis. The fistula was surgically managed by aortic resection and primary repair of the aorta, and patch repair of the left main bronchus over a Polyflex covered bronchial stent. When haemoptysis occurs in a patient with a history of bronchial stent implantation, the presence of an aorto-bronchial fistula should be considered. Early diagnosis offers the only possibility of recovery through a lifesaving surgical procedure.Entities:
Mesh:
Year: 2001 PMID: 11509298 DOI: 10.1016/s1010-7940(01)00836-3
Source DB: PubMed Journal: Eur J Cardiothorac Surg ISSN: 1010-7940 Impact factor: 4.191