Literature DB >> 11508083

Brånemark Novum: prosthodontic and dental laboratory procedures for fabrication of a fixed prosthesis on the day of surgery.

P Engstrand1, U Nannmark, L Mårtensson, I Galéus, P I Brånemark.   

Abstract

PURPOSE: The purpose of this report is to describe a new technique to fabricate and deliver an implant-supported fixed prosthesis to the patient on the day of surgery, and to propose a protocol for the prosthodontic and dental laboratory procedures.
MATERIALS AND METHODS: The development of the Brånemark Novum prosthodontic protocol is reviewed, and clinical and dental laboratory assessments and methods are described.
RESULTS: The total treatment time to fabricate a permanent implant-supported fixed prosthesis in the mandible can be reduced to 1 day with the Brånemark Novum technique. The new method includes a precise surgical technique using drilling templates for predetermined implant positions, a rigid splinting of the implants immediately after placement, the use of a prefabricated titanium framework, and elimination of implant impression procedures.
CONCLUSION: With the technique described in this report, it is possible to provide patients with a permanent implant-supported fixed prosthesis in the mandible on the day of implant surgery. Patient benefits are obvious, with drastically reduced total treatment time, lower cost, and fewer clinical visits.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11508083

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  2 in total

1.  A Study of Human Mandibles of Indian Origin for Available Bone After Bone Reduction for Trefoil Concept: A In-Vitro Human Cadaver Mandible Study.

Authors:  R Chowdhary; S Amber; N K Sonahalli
Journal:  J Maxillofac Oral Surg       Date:  2020-08-05

2.  Mandibular full-arch fixed prostheses supported by three-dental-implants: A protocol of an overview of reviews.

Authors:  Kelvin I Afrashtehfar; Rosalin A Moawad; Afaf W F-Eddin; Hom-Lay Wang
Journal:  PLoS One       Date:  2022-04-04       Impact factor: 3.240