Literature DB >> 11507805

Early bond strength and durability of bond between a ceramic material and chemically-cured or dual-cured resin luting agent.

K Kamada1, K Yoshida, M Atsuta.   

Abstract

PURPOSE: To evaluate the influence of the different polymerization types of two chemically-cured (Panavia 21 and Super-Bond C&B) and three dual-cured (Panavia Fluoro Cement, Clapearl DC, and Vita Cerec Duo Cement) resin luting agents on the early bond strengths and durability of bond to a Cerec 2 ceramic material.
MATERIALS AND METHODS: The Cerec 2 ceramic specimens were prepared with No. 600 silicon carbide paper and their surfaces were etched with phosphoric acid gel, and applied with silane coupling agent. Two sizes of specimens were then bonded together with each of the five luting agents. Shear bond tests were performed 10 mins or 20 mins after preparing specimens, storage in water at 37 degrees C for 24 hrs, and/or 20,000 thermocycles between 4 degrees C and 60 degrees C water baths.
RESULTS: The specimens bonded with one of the three dual-cured resin luting agents showed almost the same shear bond strengths for all four storage conditions. However, two chemically-cured resin luting agents exhibited much lower shear bond strengths at 10- and 20-min intervals than at 0 and 20,000 thermocycles. Three dual-cured resin luting agents showed significantly higher bond strengths than two chemically-cured resin luting agents at 10- and 20-min intervals.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11507805

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  4 in total

1.  Effect of etchant variability on shear bond strength of all ceramic restorations - an in vitro study.

Authors:  Seema Pattanaik; Aarti P Wadkar
Journal:  J Indian Prosthodont Soc       Date:  2011-04-30

2.  Microtensile bond strength of self-adhesive luting cements to ceramics.

Authors:  Tomoko Abo; Shigeru Uno; Masahiro Yoshiyama; Toshimoto Yamada; Nobuhiro Hanada
Journal:  Int J Dent       Date:  2012-04-23

3.  Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study.

Authors:  Monika Bjelopavlovic; Michael Weyhrauch; Herbert Scheller; Stefan Wentaschek; Karl Martin Lehmann
Journal:  Materials (Basel)       Date:  2022-10-07       Impact factor: 3.748

4.  Influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin.

Authors:  Claudio Poggio; Marco Pigozzo; Matteo Ceci; Andrea Scribante; Riccardo Beltrami; Marco Chiesa
Journal:  Dent Res J (Isfahan)       Date:  2016 Mar-Apr
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.