Literature DB >> 11507121

Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau: a minimum five-year follow-up study.

K J Saleh1, P Sherman, P Katkin, R Windsor, S Haas, R Laskin, T Sculco.   

Abstract

BACKGROUND: There is little information in the literature regarding the outcome of total knee arthroplasty following open reduction and internal fixation of fractures of the tibial plateau. The goal of this study was to evaluate the results of such procedures after a minimum of five years of follow-up.
METHODS: We retrospectively analyzed the outcomes of fifteen total knee arthroplasties performed at an average of 38.6 months (range, eight months to eleven years) after open reduction and internal fixation of a fracture of the tibial plateau in fifteen consecutive patients. The average duration of follow-up after the total knee arthroplasty procedures was 6.2 years (range, 5.4 to 11.1 years). The average age of the patients was fifty-six years (range, thirty-seven to sixty-eight years) at the time of the arthroplasty. We evaluated the outcomes on the basis of the Hospital for Special Surgery knee score, the Short Form-36 score, and radiographs of the knees.
RESULTS: The average Hospital for Special Surgery knee score was 51 points (range, 20 to 74 points) before the arthroplasty, and it increased to 80 points (range, 44 to 91 points) postoperatively. Four knees were scored as excellent, eight had a good result, one was rated as fair, and two had a poor result. The average Short Form-36 scores were 58.0 points for general health, 72.4 points for bodily pain, 72.1 points for mental health, 58.3 points for physical functioning, 84.6 points for physical role functioning, 81.0 points for social functioning, and 57.7 points for vitality. The average active postoperative arc of motion was 105 degrees (range, 70 degrees to 135 degrees ) compared with 87 degrees (range, 20 degrees to 125 degrees ) preoperatively. Incomplete radiolucencies were noted on all of the postoperative radiographs made after the total knee arthroplasties. There was a high rate of infection (three patients), patellar tendon disruption (two patients), and postoperative secondary procedures (three patients required closed manipulation). The patients with infection were considered to have a failure of treatment: two required arthrodesis, and one required a two-stage exchange.
CONCLUSION: On the basis of our results, we concluded that total knee arthroplasty after open reduction and internal fixation of a fracture of the tibial plateau decreases pain and improves knee function, but the procedure is technically demanding and is associated with a high failure rate (five of fifteen).

Entities:  

Mesh:

Year:  2001        PMID: 11507121     DOI: 10.2106/00004623-200108000-00002

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  31 in total

1.  Subchondral screw abutment: does it harm the joint cartilage? An in vivo study on sheep tibiae.

Authors:  Michael Goetzen; Ladina Hofmann-Fliri; Daniel Arens; Stephan Zeiter; Ursula Eberli; Geoff Richards; Michael Blauth
Journal:  Int Orthop       Date:  2017-01-31       Impact factor: 3.075

2.  Total knee arthroplasty implanted with and without kinematic navigation.

Authors:  R Hart; M Janecek; A Chaker; P Bucek
Journal:  Int Orthop       Date:  2003-08-26       Impact factor: 3.075

3.  Outcomes after knee arthroplasty in extra-articular deformity.

Authors:  Fabricio Bolpato Loures; Wesley Correia; João Henrique Reis; Rodrigo Sattamini Pires E Albuquerque; Alan de Paula Mozela; Eduardo Branco de Souza; Phelippe Valente Maia; João Maurício Barretto
Journal:  Int Orthop       Date:  2018-09-14       Impact factor: 3.075

4.  Increased Risk of Revision, Reoperation, and Implant Constraint in TKA After Multiligament Knee Surgery.

Authors:  Steven I Pancio; Paul L Sousa; Aaron J Krych; Matthew P Abdel; Bruce A Levy; Diane L Dahm; Michael J Stuart
Journal:  Clin Orthop Relat Res       Date:  2017-01-13       Impact factor: 4.176

5.  A 3 year minimum follow up of Endoprosthetic replacement for distal femoral fractures - An alternative treatment option.

Authors:  A Atrey; N Hussain; O Gosling; P Giannoudis; A Shepherd; S Young; J Waite
Journal:  J Orthop       Date:  2017-01-10

6.  Total knee arthroplasty after complex tibial plateau fractures.

Authors:  R Civinini; Christian Carulli; F Matassi; M Villano; M Innocenti
Journal:  Chir Organi Mov       Date:  2009-07-16

Review 7.  [Posttraumatic deformities of the knee joint : Intra-articular osteotomy after malreduction of tibial head fractures].

Authors:  K-H Frosch; M Krause; J Frings; T Drenck; R Akoto; G Müller; J Madert
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

8.  [Knee arthroplasty in patients with posttraumatic arthritis].

Authors:  S Hankemeier
Journal:  Unfallchirurg       Date:  2013-05       Impact factor: 1.000

9.  [Trauma hospital. Knee arthroplasty as primary therapy for proximal tibial fracture].

Authors:  N Schwarz; W Buchinger; M Mähring; R Schedl; H K Widhalm
Journal:  Unfallchirurg       Date:  2008-11       Impact factor: 1.000

10.  Posttraumatic osteoarthritis caused by battlefield injuries: the primary source of disability in warriors.

Authors:  Jessica C Rivera; Joseph C Wenke; Joseph A Buckwalter; James R Ficke; Anthony E Johnson
Journal:  J Am Acad Orthop Surg       Date:  2012       Impact factor: 3.020